My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Ord 1988-080
San-Marcos
>
City Clerk
>
02 Ordinances
>
1980 s
>
1988
>
Ord 1988-080
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/10/2007 11:35:07 AM
Creation date
8/10/2007 11:35:07 AM
Metadata
Fields
Template:
City Clerk
City Clerk - Document
Ordinances
City Clerk - Type
Amending
Number
1988-80
Date
10/24/1988
Volume Book
93
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />In phase I two wells should be constructed in the Lowmans I Ranch <br />development on Centerpoint Road, near the location of the <br />proposed standpipe. This location will service the proposed <br />developments supplying water to the elevated storage tank, to be <br />located on the far western side of the Lowman Ranch development. <br />A well is to be constructed at the 770 contour on McCarty Lane in <br />phase I to service the new unspecified development, as well as the <br />lower pressure plane in the future. A well is proposed to be <br />constructed in phase II at Well Site A to supply water to the lower <br />pressure plane being serviced at that time. In phase III an <br />additional well is proposed to be constructed at Well Site A to <br />supply water to the remainder of the lower pressure plane through <br />the year 2005 as well as the proposed elevated tank located at Well <br />Site A. <br /> <br />The following well supply facilities are recommended to serve the <br />study area; <br /> <br />TABLE 5 <br />Well Requirements <br /> <br /> Daily Average Required Total <br /> Flow Supply Flow Number of <br />Design Phase gpm gpm Wells Required <br />I 317 634 2 <br />II 1,075 2,150 3 <br />III 2,290 4,580 5 <br /> <br />D. <br /> <br />Storage Facilities <br /> <br />The Texas Department of Health requires 185 gallons per capita of <br />total water storage and 55 gallons per capita of eleyated storage <br />for an approved system. The elevated storage must be able to <br />maintain 35 psi during normal conditions. The proposed standpipe <br /> <br />JONES ð NEUSE <br /> <br />r <br />j <br /> <br />"C; <br />
The URL can be used to link to this page
Your browser does not support the video tag.