My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Ord 2015-010/International fire code amendments adoption
San-Marcos
>
City Clerk
>
02 Ordinances
>
2010's
>
2015
>
Ord 2015-010/International fire code amendments adoption
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/23/2015 1:16:12 PM
Creation date
3/23/2015 1:09:31 PM
Metadata
Fields
Template:
City Clerk
City Clerk - Document
Ordinances
City Clerk - Type
Revising
Number
2015-10
Date
3/17/2015
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
around the circumference of fire hydrants except as otherwise required or approved. <br />Section 507 is amended by adding the following: <br />507.5.7. Marking. The location of all fire hydrants shall be identified with a blue <br />reflective road dot placed near the center of the roadway in front of the hydrant. <br />Section 604.2.14.3 is amended to read as follows: <br />604.2.14.3. Emergency systems. Exit signs, exit illumination as required by Chapter <br />10, and elevator car lighting are classified as emergency systems and shall operate <br />within 10 seconds of failure of the normal power supply for egress lighting and shall <br />be capable of being transferred to the standby source. <br />Section 605.9 is amended to read as follows: <br />605.9. Temporary wiring. Temporary wiring for electrical power and lighting <br />installations is not allowed to exceed a period of 90 days. This includes decorative <br />holiday lighting, carnivals and similar purposes. Temporary wiring methods shall <br />meet the applicable provisions of the ICC International Electrical Code or National <br />Electrical Code as adopted. Temporary wiring for construction purposes shall be <br />removed at the end of construction. <br />Section 605 is amended by adding the following: <br />605..1...1....:..��. Labels for disconnecting means. Each disconnecting means for each <br />service feeder, or branch circuit shall be legibly marked to indicate its purpose at the <br />point where it originates. Where the service feeder or branch is located on a building <br />or other structure, a description of the device and address of the building must be <br />prominently displayed utilizing a marking of sufficient durability to withstand the <br />environment involved. A list of acceptable marking devices and labels can be <br />obtained through the electric utility department. <br />Section 903.1 is amended by adding the following: <br />903.1.2 More restrictive section applies. Where fire sprinklers are required in <br />other sections of this code, the most restrictive requirement will apply to methods <br />of construction, installation, or other system requirements. <br />903.2. 10 is amended to read as follows: <br />-10- <br />
The URL can be used to link to this page
Your browser does not support the video tag.