Res 2019-057/approving an amended and restated Interconnection Agreement with the LCRA Transmission Services Corporation (“LCRA TSC”) which includes, among other items, the addition of a Mobile Transformer Tap at the Ranch Road 23 Substation; approving a
San-Marcos
>
City Clerk
>
03 Resolutions
>
2010's
>
2019
>
Res 2019-057/approving an amended and restated Interconnection Agreement with the LCRA Transmission Services Corporation (“LCRA TSC”) which includes, among other items, the addition of a Mobile Transformer Tap at the Ranch Road 23 Substation; approving a
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/17/2019 12:56:54 PM
Creation date
4/29/2019 10:07:26 AM
Metadata
Fields
Template:
City Clerk
City Clerk - Document
Resolutions
City Clerk - Type
Agreement
Number
2019-57
Date
4/2/2019
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
• LCRA TSC will provide SMEU with floor space (as available and as necessary) <br />in its control houses for the installation of SMEU required relay panel boards and <br />equipment. <br />• SMEU shall supply and provide metering current transformers from power <br />transformer T2 for LCRA TSC metering. <br />• SMEU shall supply and provide 12.5 -kV bus potential transformer PT2 for LCRA <br />TSC metering. <br />• LCRA TSC will provide tripping and close inhibit contacts from LCRA TSC's <br />138 -kV differential & breaker failure relaying panel to SMEU's circuit switcher <br />CS2555 relaying panel. <br />• LCRA TSC will provide tripping and close inhibit contacts from LCRA TSC's <br />138 -kV bus differential & breaker failure relaying panel to SMEU's circuit <br />switcher CS9555 relaying panel. <br />• SMEU will provide breaker failure initiate contacts from SMEU's 138 -kV circuit <br />switcher CS2555 relaying panel to LCRA TSC's 138-1cV-bus differential & <br />breaker failure relaying panel. <br />• SMEU will provide breaker failure initiate contacts from SMEU's 138 -kV circuit <br />switcher CS9555 relaying panel to LCRA TSC's 138 -kV bus differential & <br />breaker failure relaying panel. <br />• SMEU will supply and provide relaying current transformers from SMEU's <br />Transformer T2 for use by LCRA TSC in LCRA TSC's 138 -kV bus differential <br />relaying scheme. <br />• LCRA TSC and SMEU shall design, provide, and coordinate their respective <br />protection system equipment so that adjacent zones of protection overlap, in <br />accordance with ERCOT Nodal Operating Guides. <br />-----The remainder of this page has intentionally been left blank----- <br />LCRA TSC — San Marcos Electric Utility Amendment No. I Page 6 of 13 <br />