Laserfiche WebLink
Revised Agreement for Professional Services Plummer Project No. Barnes Dr,San Marcos <br /> the record locations,adjusted to found above ground features. CONSULTANT will survey visible above ground <br /> improvements (buildings, fences, driveway, etc.) and visible evidence of utilities (valves, manholes, meters, <br /> etc.) within the project site. CONSULTANT will locate the flowlines of culverts, storm manholes and other <br /> features that are used to convey or contain storm waters. Electronic depths will be provided at points along <br /> located toneable utilities in a CAD base file format. The Engineering Design Survey map will depict the <br /> elevation contours, right-of-way lines,above ground visible improvements,evidence of utilities, underground <br /> utility lines found, benchmarks, culverts with flowline elevations, and other storm water features. Lines and <br /> other information representing the perimeter of the property shown on the Engineering Design Survey will be <br /> for general descriptive purposes only. The survey data will be referenced to the Texas Coordinate System of <br /> 1983, South Central Zone (NAD 83 (2011)) and the North American Vertical Datum of 1988 (NAVD88, Geoid <br /> 18). All coordinate will be grid values. <br /> Deliverables will be in electronic file format(Civil 3D 2021), no hard copy maps will be produced. A signed and <br /> sealed "Survey Certificate"will be issued in a memorandum format stating: <br /> "The survey data collected between the dates on [date] and [date] provided to K-Friese and Associates <br /> was surveyed under my direction and supervision. This survey data is referenced to the Texas Coordinate <br /> System of 1983, South Central Zone (NAD 83 (2011)) with elevations referenced to the North American <br /> Vertical Datum of 1988(NAVD88, Geoid 18). All coordinates are grid values." <br /> AS-BUILT SURVEY <br /> CONSULTANT will produce an As-Built Survey of 2 or 3 manholes to include rim elevations and pipe flowlines <br /> for the newly constructed manholes. The manholes will be referenced to the previous project datum. <br /> Deliverables will be in electronic file format (Civil 3D 2021), no hard copies will be produced. A signed and <br /> sealed "Survey Certificate"will be issued in a memorandum format stating: <br /> "The survey data collected between the dates on [date] and [date] provided to K-Friese and Associates <br /> was surveyed under my direction and supervision. This survey data is referenced to the Texas Coordinate <br /> System of 1983, South Central Zone (NAD 83 (2011)) with elevations referenced to the North American <br /> Vertical Datum of 1988 (NAVD88, Geoid 18)." <br /> ASSUMPTIONS: <br /> 1. CLIENT will provide right-of-entry to CONSULTANT onto the Subject Site. <br /> EASEMENT SURVEY <br /> CONSULTANT will write an easement description and draft an easement sketch to accompany the description <br /> for one (1) easement parcel across Lot 1, Block 3,THERMON IND PARK#2 UNIT#2,that meets the standards <br /> set forth by the Texas Board of Professional Engineers and Land Surveyors. The preparation of the easement <br /> dedication document will not be part of this task. <br /> Page 7 of 9 <br />