Section 907.6 shall be installed in Group E educational occupancies. When automatic sprinkler systems or smoke <br />detectors are installed, such systems or detectors shall be connected to the building fire alarm system. An approved <br />smoke detection system shall be installed in Group E day care occupancies. Unless separated by a minimum of 100' <br />open space, all buildings, whether portable buildings or the main building, will be considered one building for alarm <br />occupant load consideration and interconnection of alarm systems. <br />Exceptions: <br />1. {No change.} <br />1.1. Residential In -Home day care with not more than 12 children may use interconnected single <br />station detectors in all habitable rooms. (For care of more than five children 2 1/2 or less years of <br />age, see Section 907.2.6.) <br />{No change to remainder of exceptions.} <br />Section 907.2.10; change to read as follows: <br />907.2.10 Group S. A manual fire alarm system that activates the occupant notification system in accordance with <br />Section 907.5 shall be installed in Group S public- and self -storage occupancies three stories or greater in height for <br />interior corridors and interior common areas. Visible notification appliances are not required within storage units. <br />Exception: {No change.} <br />Section 907.2.13, Exception #3; change to read as follows: <br />Open air portions of buildings with an occupancy in Group A-5 in accordance with Section 303.1 of the <br />International Building Code; however, this exception does not apply to accessory uses including but not limited <br />to sky boxes, restaurants, and similarly enclosed areas. <br />Section 907.4.2.7; add to read as follows: <br />907.4.2.7 Type. Manual alarm initiating devices shall be an approved double action type. <br />Section 907.4.2.7; add to read as follows: <br />907.4.2.7 Type. Manual alarm initiating devices shall be an approved double action type. <br />Section 907.6.1.1; add to read as follows: <br />907.6.1.1 Wiring Installation. All fire alarm systems shall be installed in such a manner that a failure of any single <br />initiating device or single open in an initiating circuit conductor will not interfere with the normal operation of other <br />such devices. All signaling line circuits (SLC) shall be installed in such a way that a single open will not interfere with <br />the operation of any addressable devices (Class A). Outgoing and return SLC conductors shall be installed in <br />accordance with NFPA 72 requirements for Class A circuits and shall have a minimum of four feet separation <br />horizontal and one foot vertical between supply and return circuit conductors. The initiating device circuit (IDC) <br />from a signaling line circuit interface device may be wired Class B, provided the distance from the interface device <br />to the initiating device is ten feet or less. <br />Section 907.6.1.2; add to read as follows: <br />(Supp. No. 35, Update 4) <br />Page 15 of 44 <br />Created: 2022-12-02 10:13:41 [EST] <br />