Laserfiche WebLink
Docusign Envelope ID: BB27E2CA-90E7-44DF-ACD6-60284C2E92F6 `XHIBIT 1 <br /> ATTACHMENT A <br /> CITY OF SAN MARCOS <br /> WALLACE ADDITION SUBDIVISION IMPROVEMENTS <br /> SCOPE OF SERVICES <br /> Project Understanding <br /> The work to be performed by Tetra Tech, Inc. (the Consultant) under this contract will consist of <br /> providing Preliminary Design, Design Phase (60%, 90%, 99%, 100% Documents), and Bid and <br /> Construction Phase Services for the Wallace Addition Subdivision Improvements. The project <br /> consists of replacing potable water main and sanitary sewer pipelines along Staples, Juarez, <br /> Monterey, Luciano Flores, Durango, Saltillo, Laredo, and Tampico streets. Approximately <br /> 13,700 linear feet (LF) potable water pipelines and 9,800 LF of sanitary sewer lines are to be <br /> replaced in the project. The proposed diameter of water and sewer lines will range from 8 to 12- <br /> inches. The preliminary design phase will also evaluate drainage, street, and sidewalk <br /> improvements needed in the subdivision. Available funds will dictate which improvements will be <br /> included in subsequent phases of the project. <br /> Basic Scope of Services <br /> I. General <br /> A. Data Collection/Review: The City has a lot of relevant information (Geotech, surveying and <br /> Subsurface Utility Engineering (SUE) which will be provided to the Consultant as part of existing <br /> data. After reviewing the data, the Consultant will prepare a Data Request from the City prior to the <br /> initial Project Coordination Meeting. The Consultant will review the pertinent documentation to <br /> inform subsequent project evaluations. <br /> B. Topographic and Tree Survey: During the Preliminary Engineering Phase, the Consultant will have <br /> McCray and McCray prepare any additional topographic and tree survey within the public right of <br /> way (ROW) and utility easement, as shown in the attached exhibits (Exhibits A, B, and C). The <br /> Consultant will prepare an electronic map showing the following: <br /> a. Horizontal Control: The survey will be provided in Texas State Plane, South Central <br /> Zone, NAD 83, Grid coordinates with a note defining the Grid to Surface Scale factor. <br /> b. Vertical Control: Elevations will be obtained using NAVD 88, Central Zone, EPOCH <br /> 2010.00, Geoid 2018 and at least three (3) benchmarks will be established onsite, and <br /> descriptions will be provided on the drawing. <br /> c. Full topography with enough detail to prepare 1' contours for the project area as identified <br /> in Exhibit A, including portions of Staples Road, Tampico Street, Juarez Avenue, Laredo <br /> Street, Saltillo Street, Durango Street, Cape Road, Monterrey Street and Luciano Flores <br /> Boulevard. <br /> d. Locate and identify all above ground features within the survey limits including buildings, <br /> fences, sidewalks, driveways, handicap ramps, guardrails, signs, visible utilities including <br /> manholes, water meters, top of nut of water and gas valves, telecom boxes, utility poles <br /> and mailboxes. <br /> e. Invert elevations of manholes, drainage pipes and culverts shall be identified along with <br /> size/type of the pipes. <br /> f. Locate and identify types of existing pavement surfaces for streets, sidewalks and <br /> driveways. <br /> g. Existing conditions survey to include boundary information and ROW and easement limits <br /> within project area. Identify all visible and above grade utilities, and manholes with invert <br /> elevations and tied to existing control points/City benchmarks (if any). <br /> h. Underground site utilities will be located by Dig-Tess only. <br /> i. Existing trees, size and type (at minimum caliper inches required by City CIP)—24" and <br /> above caliper for Native Oaks, Elms, Madrone, and Pecan, Celtis Occidentalis <br /> (Hackberry), Juniperus Virginiana, Juniperus Ashei (Common Cedar), Chinaberry, <br /> 1 <br />