My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Res 2008-053
San-Marcos
>
City Clerk
>
03 Resolutions
>
2000 s
>
2008
>
Res 2008-053
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/4/2008 2:20:08 PM
Creation date
4/22/2008 11:10:05 AM
Metadata
Fields
Template:
City Clerk
City Clerk - Document
Resolutions
City Clerk - Type
Agreement
Number
2008-53
Date
4/15/2008
Volume Book
175
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
h) Classifications of leaks such as: <br />1) Main line; <br />2) Manhole; <br />3) Public service line; and <br />4) Private service line. <br />1.5.5 Utilize smoke testing to facilitate other tasks as required <br />1.5.6 If the linear footage of the sewer lines in the two designated areas varies from the present <br />estimate, consult with the City's representative to define target smoke test quantities. The <br />Consultant will record data for each smoke test in Microsoft Access 2000 format to facilitate <br />data upload to the City's Information Management System. The Consultant will follow all City <br />smoke testing procedures. <br />1.5.7 Report surcharged pipelines, pipelines with sags and/or blockages to the City on a weekly <br />basis. The Consultant will provide immediate notification of field conditions that could cause <br />damage to persons or property. Any public meetings, if required for this Project, should be <br />conducted before the smoke testing operations begin. <br />1.5.8 Prepare a technical memorandum outlining the results of this task for review by the City. <br />The technical memorandum will provide tabular and graphical listings of inspected system assets <br />and the location and type of defects. The Consultant will provide both hardcopy and electronic <br />formats of this data. The Consultant will provide the electronic data in Microsoft Access 2000 <br />format. <br />1.6 TASK 5 -DYED WATER FLOODING/LEAK QUANTIFICATION <br />The Consultant will: <br />1.6.1 Identify interconnections, pinpoint inflow sources and quantify selected collection line, <br />manhole, and service line leaks that were identified based on the results of previous tasks. The <br />Consultant will base leak quantification estimates on field measurements and empirical values <br />developed from past experience. <br />1.6.2 Perform leak quantification for approximately 15 locations, to be determined during <br />smoke testing, using portable weirs or hydrostatic devices in conjunction with dyed water <br />flooding. The Consultant will provide the City's representative with a listing of candidates for <br />sanitary sewer dyed water flooding for approval before the operation begins. The Consultant will <br />record the dyed water testing on DVD in WMP or compatible format. The Consultant will use <br />this information to evaluate I/I rates and compare to flow monitoring results to determine <br />quantities of I/I. The Consultant will perform a portion of the dye flooding in conjunction with <br />Task 7. <br />1.6.3 Prepare a technical memorandum outlining the results of this task for review by the City. <br />GSWW, Inc. Contract <br />5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.