My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Ord 2005-048
San-Marcos
>
City Clerk
>
02 Ordinances
>
2000 s
>
2005
>
Ord 2005-048
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/2/2008 1:46:54 PM
Creation date
3/3/2006 10:24:53 AM
Metadata
Fields
Template:
City Clerk
City Clerk - Document
Ordinances
City Clerk - Type
Code of Ordinances
Number
2005-48
Date
7/5/2005
Volume Book
162
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />or other system requirements. <br /> <br />903.2.9 is amended to read as follows: <br /> <br />903.2.9 Group S-2. An automatic sprinkler system shall be provided throughout all <br />buildings classified as Groups S-2 having a fire area exceeding 18,000 square feet. An <br />automatic sprinkler system shall be provided throughout buildings classified as enclosed <br />parking garages in accordance with Section 406.4 or where located beneath other groups. <br /> <br />903.2 is amended by adding the following: <br />903.2.14. Other occupancy classifications. An automatic sprinkler system shall be provided <br />throughout all buildings classified as Group B or Group F-2 having a fire area exceeding <br />18,000 square feet. <br /> <br />903.2.15 Additions and Expansions. Any building constructed after April 1, 2002 that <br />exceeds 18,000 sq. ft. or any attached construction, alteration, or addition to an existing <br />structure of any group that causes the structure to exceed 18,000 sq. ft. For purposes ofthis <br />section, an automatic fire sprinkler system is to be installed in the non-conforming or existing <br />structure in addition to the new construction area. <br /> <br />903.4 Exception 3 is deleted. <br /> <br />The following definition in Section 1002 is amended to read as follows: <br /> <br />MEANS OF EGRESS. A continuous and unobstructed path of egress travel from any <br />occupied portion of a building or structure to a public way. The means of egress may include <br />any combination of horizontal or vertical pathways or travel. A means of egress consists of <br />three separate and distinct parts: the exit access, the exit, and the exit discharge. <br /> <br />1507.8 and 1507.9 are deleted and replaced with the following: <br /> <br />1507.8. Wood shingles and shakes are prohibited as new or replacement roofing material, <br />except that wood shingles and shakes as the primary roofing surface in existence on January 1, <br />2001 may be replaced with UL listed fire retardant shingles or shakes that are approved by the <br />fire marshal. <br /> <br />3001 is amended by adding the following: <br /> <br />3001.5 If there is a conflict between state law or the International Building Code, the most <br />restrictive provision shall apply. <br /> <br />3305 is amended by adding the following: <br /> <br />3305.2 Contractors shall ensure that every construction, remodel, repair, or renovation site has <br />a method of containment for trash and debris. The contractor shall ensure that the trash and <br />debris is removed from the site on a regular basis so that the site is maintained in a clean, <br />sanitary, and safe condition at all times. <br /> <br />9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.