<br />1.3.3 Provide model output in Power Point compatible graphic format for use in <br />presentations by the City. Model will include emissions measured at the main lift station <br />and siphon. <br /> <br />1.3.4 Assess emissions measured, impacts on surrounding neighborhoods, effectiveness <br />of existing control technologies, and other factors, and develop life-cycle cost projections <br />for key odor control technologies to be considered by the City. It is anticipated that these <br />alternatives will include: <br /> <br />b) domes or low profile covers on the primary clarifiers, <br />c) rehabilitation of existing chemical scrubbing systems, <br />d) installation of a centralized treatment complex (biofiltration, chemical <br />scrubbing, and/or carbon treatment, as determined appropriate, <br />e) installation of an in-plant foul air collection system, <br />f) addition of controls at the main lift station or siphon, if determined to be <br />appropriate, <br />g) non-capital improvements, possibly including enhanced odor event response <br />procedures, alternate plant operating protocol, or other procedures not <br />necessarily involving capital investment, <br />h) chemical introduction at selected location, possibly including continued Iron <br />Salt dosage, <br />i) Corrosion control will be considered in covered areas and elsewhere as <br />appropriate. <br /> <br />1.3.5 Prepare and deliver 5 copies of a technical memorandum describing and <br />interpreting model results. Model results showing the projected effectiveness of various <br />odor control technologies evaluated will be included, as will the results of the life-cycle cost <br />analyses of alternatives. <br /> <br />1.3.6 Meet with City personnel to discuss findings of Task II prior to preparing the master <br />plan document described in Task III. It is understood that considerations of collection <br />system odor abatement needs, for this evaluation, will be confined to the Main Lift station <br />and adjacent 3-barrel siphon. <br /> <br />1.4 TASK 3 - PREPARE ODOR ABATEMENT MASTER PLAN REPORT <br /> <br />1.4.1 Compile information from Tasks I and II and prepare a "Master Plan" document <br />describing recommended odor abatement, their relative priorities, and projected capital and <br />operating costs of each. Engineer understands that report will be used by City for capital <br />improvement planning purposes. Five copies of draft report will be submitted for City <br />review. Each major control alternative recommended will include a brief listing of other <br />successful applications (locations, size, years of service) of the recommended technology. <br /> <br />1.4.2 Address City comments and finalize Master Plan report. Ten copies of the final <br />report will be delivered to the City. <br /> <br />3 <br />