My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Res 1995-082
San-Marcos
>
City Clerk
>
03 Resolutions
>
1990 s
>
1995
>
Res 1995-082
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/19/2007 10:28:19 AM
Creation date
6/19/2007 10:28:19 AM
Metadata
Fields
Template:
City Clerk
City Clerk - Document
Resolutions
City Clerk - Type
Agreement
Number
1995-82
Date
4/28/1995
Volume Book
118
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br /> , 1911x' <br /> "WILTEL <br /> Meridian 1: <br /> .... Panels should be located in the equipment room. <br /> :::: <br /> .0" No lighting, air conditioning, heating, generators or motors shall be serviced <br /> '... <br /> .... <br /> from this equipment room panel. <br /> :.:- In areas where isolated ground systems are permissible,this panel will provide <br /> .;.; <br /> sufficient ground connection points on the isolated ground plate or bar to handle <br /> the AC circuit grounds as well as the other ground reference conductors <br /> associated with the Meridian 1. <br /> Service Receptacles <br /> One dedicated outlet per pedestal (column) is a typical requirement for AC systems. <br /> For DC systems, or if reserve power is being used, the receptacles or conduit will <br /> serve the centralized rectifiers or UPS system directly, with power then routing to the <br /> columns. <br /> Unless otherwise specified, these circuits should be rated for 30 Amps. All circuits <br /> must be: <br /> ~:: Wired and fused independently of all receptacles. <br /> '", Tagged at the power panel to prevent unauthorized interruption of power. <br /> "', <br /> "', <br /> :::: Not controlled by a switch. <br /> .0', <br /> The NEMA receptacle types are as follows: < <br /> ~~ Isolated Ground Systems: IG-L6-30 <br /> System Grounding Requirements - Essential to trouble-free system operation and the <br /> safety of personnel is the employment of proper grounding. The Meridian 1 has several <br /> different grounds and signal returns that are generally referred to as grounds: logic <br /> return, battery return (for DC systems), AC "green wire" ground (in AC systems), and <br /> the personal hazard equipment ground. <br /> The Meridian 1 does not, by design, need an AC Isolated Ground (IG) system (though this <br /> may be required by local codes), but it does need a single point ground system. This <br /> means that each of the various grounds, from each of the columns, should terminate at <br /> a single connection point before attaching to the actual ground reference at the main <br /> AC panel or transformer. The single-point ground may be implemented either by the use <br /> of the Isolated Ground bus in the AC panel, or by a separate logic return equalizing <br /> bus for battery returns and logic returns where a non-isolated AC system is used. <br /> The following must also be observed to implement the single-point ground: <br /> :::: All ground conductors must be in accordance with local codes and terminate in <br /> a manner that is permanent, resulting in low impedance connections. <br /> :;:: All terminations should be accessible for inspection and maintenance. <br /> Customer: ~ -- <br /> Revised 9/24/94 Page 5 of 10 WilTel: <br />
The URL can be used to link to this page
Your browser does not support the video tag.