Laserfiche WebLink
<br /> 13~X <br /> PHOTOSYNTHETIC PERIPHYTON TREATMENT SYSTEMS <br /> Following contract termination with Hazcorp Environmental and <br /> removal of their equipment, two groundwater treatment systems were <br /> designed and installed, one in the "Old Yard" and another in the <br /> "New Yard." <br /> The two '_reatment systems were designed to facilitate growi-~ of <br /> photosynthetic periphyton (algae and bacteria). Each system <br /> consists of four series-operated 1700 gallon translucent <br /> polyethylene tanks. <br /> The domed tanks were oriented to receive maximum sunlight and <br /> spaced so that one tank did not shade another. The flat-bottomed <br /> tanks were placed on a level sand bed and an outlet surface-baffled <br /> standpipe placed in each for water level control. Tanks were <br /> connected by piping near ground. <br /> A hand-crafted air-lift pumping device was placed in bottom center <br /> of each tank. The pump barrel is a section of PVC pipe 3 inches in <br /> diameter and 30 inches in length. A helix, fashioned by threading <br /> sections of 1/2 inch diameter PVC tubing onto a steel shaft, was <br /> glued into barrel. The pump was mounted on a weighted base to <br /> maintain it in an upright position. An airline fitting passing <br /> through barrel wall to center with an upturned "elbow", was placed <br /> near bottom of the pump barrel. A Gast diaphragm air compressor, <br /> mounted in a protective shelter and fitted with a manifold and four <br /> ) air flow control valves, is used to operate pumping devices. The <br /> ....... rated air flow of the 1/8 HP compressor is 1.1 cfm. <br /> Extruded polyethylene mesh tubing 1.0 inch in diameter (Naltex) was <br /> used as media for attached growth of photosynthetic organisms. <br /> Tubing was cut into 54 inch lengths, with each tube bottom-weighted <br /> with a section of PVC pipe. Each tank was provided with 350 tube <br /> sections. <br /> I <br /> System inflow passes through a water meter and grit trap. <br /> Supplemental nutrient addition was not needed to sustain growth of <br /> photosynthetic organisms as analytical results of groundwater <br /> revealed phosphate content of 0.04-0.06 mglliter and nitrate <br /> content of 2.2-3.9 mg/liter. <br /> Excluding tank bottom area, solid surface area for attached growth <br /> provided by polyethylene tubes and tank side walls was some 3500 <br /> ft2. At design flow, daily hydraulic loading on media surface is <br /> 8.2 gal/ft2. Actual system throughput has varied with well yields. <br /> The BTEX in pumped wells fluctuates from zero to high levels. <br /> - 2 - <br /> pa1:;e 4 of 4 of <br /> xhibit A <br />