<br /> 6/J <br /> Page No. 1 CITY OF SAN MARCOS <br /> 06/17/93 TRANSITION PLAN <br /> OBJ TYPE PRIOR FACILITY CATEGORY PROBLEM COST REMEDY INTERtW. <br /> ESTIMATE WORK <br /> 1 A 1 AS curb rall\PS curb ramps present 250 install ramp to front door N <br /> 2 A 2 AS doors clear width 5000 replace 7 doors N <br /> 2 A 2 AS doors maneuvering space 750 reset kennel door to hinge sid N <br /> 1 A 1 AS doors thresholds 25 replace threshold N <br /> 1 A 1 AS ext route route to entrance 425 sidewalk to entrance N <br /> 1 A 1 AS landings level landings 0 landing constructed with ramp N <br /> 3 A 2 AS lavatories below-counter clearance 0 addressed with restrOOl modif N <br /> 3 A 2 AS lavatories clear floor space 0 addressed with restroom remake N <br /> 3 B 2 AS lavatories faucet controls 0 apdressed with restrOOl modif N <br /> 3 B 3 AS lavatories hot water pipes 0 addressed with restroom modif N <br /> I 3 A - 2 AS lavatories knee and toe clearances 0 addressed with sink change N <br /> 3 B 3 AS mirrors reflective edge height 0 addressed with restroom modif N <br /> 2 A 2 AS protruding obj objects from wall 200 recess hose faucet in kennel N <br /> 3 A 1 AS rest rooms access entrance door 700 replace door N <br /> 3 A 1 AS rest rooms along accessible route 0 addressed with int route N <br /> 3 A 1 AS rest rooms controls clear flor space 0 addressed with restroom modif N <br /> 3 B 1 AS rest rooms controls reach & height 0 addressed with restroom modif N <br /> 3 A 1 AS rest rooms one accessible per floor 15000 make restroom accessible N <br /> 3 A 1 AS rest rooms turning space 0 addressed with restroom modif N <br /> 4 A 2 AS seating fixed table spaces 2000 open area under counter N <br /> 4 A 2 AS seating knee clearance 0 open area under counter N <br /> 3 A 1 AS water closets clear floor space 0 addressed with restroom modif N <br /> 3 B 2 AS water closets grab bar height/width 0 addressed with restroom modif N <br /> 3 B 2 AS water closets seat height 0 addressed with restroom modif N <br /> Total 24350 <br /> 1 A 1 BP curb ramps curb ramps present 100 install ramp to curb N <br /> Total 100 <br /> 4 B 3 CA controls clear floor space 150 move temperature controls N <br /> 4 B 3 CA controls highest operable height 0 move temperature controls N <br /> 1 A 2 CA curb ramps cross slope 700 replace sidewalk N <br /> 1 A 2 CA curb ramps least slope used 500 extend ramp area N <br /> 1 A 2 CA curb ramps ramp slope 500 replace ramp to back door N <br /> 2 A 3 CA doors clear width , 1400 replace kitchen & closet doors N <br /> 1 A 2 CA doors door width 700 replace back door N <br /> 1 A 1 CA doors maneuvering space 0 addressed with landing N <br /> 2 A 3 CA doors maneuvering space 300 reset men's room & kitchen dor N <br /> 1 A 1 CA ext routes route to entrance 250 ramp: parking lot to sidewalk N <br /> 1 B 2 CA handrails handrails provided 500 add handrails N <br /> 1 A 1 CA landings level landings 625 landing at door entrance N <br /> 3 B 1 CA lavatories below-counter clearance 800 replace lavatories N <br /> 3 B 1 CA lavatories knee and toe clearance 0 addressed with replacement N <br /> Total 6425 <br /> 1 A 2 CC curb ramps ramp slope 500 install permanent ramp N <br /> 1 A 2 CC ext routes good route surface 475 build landing at ramp bottom N <br /> Total 975 <br /> 1 A 3 CCH curb ralRPS ramp slope 500 rebuild ramp at parking lot N <br /> 1 ~ 3 CCH ext routes . good route surface 1000 relevel brick walkway N <br /> 1 A 2 CCH landings level landings 500 smooth out top landing N <br /> Total 2000 <br /> 4 e 2 CH a1 a TIllS visual/audio alarms 0 add visual signal N <br /> 4 B 2 CH controls etc easily operable 0 replace alarm control type N <br /> 4 S 2 CH controls ete highest operable height 0 lower alarm controls N <br /> 2 .A 2 CH controls etc service counter size 2000 modify section of counter N <br /> 1 A 2 CH curb ramps clear of traffic 500 build landing at bottOlJ N <br />