<br /> rj; 11Þ1 <br /> .' .. <br /> Page No. 4 CITY OF SAN MARCOS <br /> 06/17/93 TRANSITION PLAN <br /> 08J TYPE PRIOR FACILITY CATEGORY PROBLEM COST REMEDY INTERNAL <br /> ESTIMATE WORK <br /> 1 A 2 MA doors door width 700 replace one exterior door N <br /> 1 A 3 MA doors thresholds 0 addressed with door replacemnt N <br /> I 4 8 3 MA fountai ns spout height 0 addressed with ~eplaceGent N <br /> 4 B 2 MA fountains spout location 650 replace fountain N <br /> 1 B 2 MA handrails handrails provided 1500 handrails on ramp to bldg N <br /> 1 A 2 I1A landings level landings 500 landing at bottom of ramp N <br /> 3 A 3 MA lavatories below-counter clearance 350 raise sink N <br /> 4 B 3 MA telephones highest operable height 0 turn over to phone company N <br /> 3 A 2 MA urinals flush controls 350 lower controls N <br /> 3 A 2 I1A urinals rim height 350 lower urinal N <br /> Total 5900 <br /> 2 A 2 MB controls etc service counter size 2000 lower section counter to court N <br /> 1 A 2 1'18 curb ramps least slope used 0 addressed with ramp rebuild N <br /> 1 A 2 MB curb ramps ramp slope 500 replace curb ramp N <br /> 1 A 2 1'18 curb ramps useable width 0 addressed with ramp replacemnt N <br /> 2 B 1 MB elevator car cont buttn braille 100 add braille N <br /> 2 B 3 1'18 elevator car control buttons 0 replace N <br /> 2 B 3 MB elevator car position indicators 0 add audible sound N <br /> 2 B 1 1'18 elevator raised/braille size 100 add braille at each floor N <br /> 1 A 1 HB ext routes route between buildings 0 addressed with sidewalk N <br /> 4 B 2 1'18 fountains clear knee space 100 raise fountain N <br /> 4 B 2 MB fountains spout location 0 change spout direction N <br /> 3 A 3 MB lavatories surface height 1500 lower counter N <br /> 4 A 3 HB meeting rooms performing areas 500 ramp to witness chair N <br /> 4 B 2 1'18 telephones highest operable height 0 353-9537 give to phone co. N <br /> 3 A 2 1'18 urinals flush controls 350 lower controls N <br /> 3 A 2 MB urinals rim height 350 lower urinal N <br /> Total 5500 <br /> 2 A 2 PH controls etc service counter size 2000 rebuild section of counter N <br /> 4 B 2 PH fountains spout height 100 lower fountain N <br /> 4 B 2 PH fountains spout location , 0 change spout direction N <br /> 1 A 2 PH landings change in direction 600 rebuild middle ramp landing N <br /> 1 A 1 PH landings clear length 0 addressed with chg in directn N <br /> 4 A 3 PH meeting rooms performing areas 500 ramp to auditorium stage N <br /> 3 A 2 PH urinals clear floor space 50 widen approach space N <br /> 3 B 2 PH water closets seat height soo lower seat N <br /> Total 37SO <br /> 4 B 2 PL controls etc highest operable height 0 move microfilm switch N <br /> 2 A 2 PL controls etc service counter size 2000 lower section of counter N <br /> 1 A 1 PL doors door width 700 replace front door N <br /> 2 A 1 Pl doors double-leaf width 2400 replace double doors N <br /> 1 A 1 PL ext routes route to entrance 425 sidewalk to front curb N <br /> 4 B 2 PL fountains clear floor space 0 addressed with replace N <br /> 4 B 2 PL fountains clear knee space 650 replace fountain N <br /> 2 B 1 Pl int route clear width 1200 lOve shelfs & furniture N <br /> 1 A 2 Pl landings change in direction 600 rebuild middle ramp landing N <br /> 1 A 1 Pl landings clear length 0 addressed with chg in directn N <br /> 3 8 2 Pl lavatories below-counter clearance 200 raise sink N <br /> 3 A 1 PL rest rooms access entrance door 1800 replace restroom. doors N <br /> 2 8 1 PL stairs continuous handrail 500 add handrail N <br /> 2 B 2 PL stairs handrail height 500 lOdi fy handrail N <br /> 4 B 2 PL telephones highest operable height 0 353-9444 give to phone co. N <br />