Laserfiche WebLink
ARTICLE 6. DOWNTOWN DESIGN STANDARDS <br />6.3. EXPRESSION REQUIREMENTS <br />6.3.1. SPECIFIC TO ZONEs T4, T5 <br />6.3.2. A minimum number of expression tools shall be applied as specified below <br />and in Tables 6.2 and 6.3, and as illustrated in Table 6.4. <br />a. Condition A, buildings with a facade width greater than 60 feet AND a <br />height greater than 2 stories: <br />i. A minimum of two horizontal expression tools is required. <br />ii. At least one vertical expression tool is required. <br />b. Condition B, buildings with a facade width greater than 60 feet OR a <br />height greater than 2 stories: <br />i. A minimum of three expression tools shall be used. <br />c. Condition C, buildings with a facade width of 60 feet or less and a height <br />of 2 stories or less: <br />i. A minimum of two expression tools shall be used. <br />6.3.3. Any combinations of the wall notch, wall offset and vertical expression line <br />alternatives shall count as only one expression alternative. <br />6.3.4. Vertical expressions shall be applied across the entire height of the facade. <br />TABLE 6.2 EXPRESSION REQUIREMENT CONDITIONS <br />CONDITION A <br />CONDITION B <br />CONDITION C <br />Height greater <br />than 2 stories <br />Height greater <br />than 2 stories <br />Building width greater than 60 feet <br />Height 2 steries� <br />ar less 2 <br />1 <br />Building width lees than 60feet <br />ar- <br />N <br />1 <br />Building width greater than 60 feet <br />San Marcos, Texas <br />SC60SMARTCOOE VERSION 10 <br />