My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Ord 2013-026/Approving amended and restated PDD for the McCarty Commons
San-Marcos
>
City Clerk
>
02 Ordinances
>
2010's
>
2013
>
Ord 2013-026/Approving amended and restated PDD for the McCarty Commons
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2013 3:05:43 PM
Creation date
6/28/2013 10:03:30 AM
Metadata
Fields
Template:
City Clerk
City Clerk - Document
Ordinances
City Clerk - Type
Approving
Number
2013-26
Date
5/28/2013
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
materials such as terra cotta and metal fascia are encouraged for architectural <br />detailing and accents where appropriate. A more articulated use of details and <br />accent materials are encouraged at building entries. <br />7.5.5 Brick masonry should not include liberal use of historical details such as quoins, <br />soldier and coursing, patterned lay -ups or, articulated window headers and sills. <br />Masonry veneers shall be consistent on all elevations and not be used as the <br />predominant material. Mortars are to be cream or natural unless specifically <br />approved by the Owner(s) of Sub -Areas "A -2 ", "B ", "C" and "D ", or the POA, as <br />applicable. Brick size shall be limited to modular. <br />7.5.6 Stone masonry joints shall be raked clean where appropriate, and held to a <br />maximum of 1" in width. A 4'x4' sample lay -up of all stone masonry is required on- <br />site, to be reviewed prior to installation of the stone. Tilt slab concrete wall <br />construction is permitted, but all exposed panels must have an architectural finish. <br />Tilt slab concrete walls shall have a smooth painted finish, sandblasted finish or a <br />light- colored, exposed aggregate finish with aggregate not to exceed 1 inch in size. <br />Concrete foundation walls shall not be exposed in excess of 12" and shall be faced or <br />finished to blend with the general architectural design of the building. <br />7.5.7 The following are prohibited except with the expressed written consent of the <br />Owner(s) of Sub -Areas "A -2 ", "B ", "C" and "D ", or the POA, as applicable: <br />• Metal structures such as sheds <br />• Standard Concrete Masonry Units <br />• Reflected Glass <br />• Clay Tile Roofs <br />• Wood Shingles <br />Metal used as a building material other than for a roof requires a Conditional Use <br />Permit (CUP) under the Land Development Code (LDC); a condition to obtaining a <br />CUP shall require consent of the Owner(s) of the Sub -Areas "A -2 ", "B ", "C" and "D ", <br />or the POA, as applicable, and must also be approved by the P &Z if required by the <br />LDC. <br />7.5.8 The use of color shall generally be restricted to earth tones or natural colors found in <br />the immediate surroundings, and shall apply equally to additions and /or alterations <br />to existing structures as well as to new detached structures. Garish or unusual colors <br />and color combinations, and /or unusual designs are discouraged. No bright, <br />unfinished or mirrored surfaces will be allowed. <br />7.6 Roofs <br />7.6.1 Sloped roofs for commercial structures within the Development should generally <br />exceed a 6:12 pitch. In order to establish harmony within the community, mansard, <br />gambrel, and A -frame roof styles will not be allowed. <br />7.6.2 All metal, roofing, flashing, or miscellaneous sheet metal, shall be factory finished or <br />have a field finish approved by the Owner(s) of Sub -Areas "A -2 ", "B ", "C" and "D ", or <br />the POA, as applicable. All exterior metals should be galvanized, or Galvalume or <br />have a 20 year guaranteed and warranted paint system, with at least a 70% Kynar <br />resin and mix in the paint. All roofing systems must have hidden mechanical <br />fasteners if possible. Any exposed fasteners must use neoprene insulators. The <br />minimum thickness for metal roofing and flashing should be 24 gauge. <br />7.6.3 Roofing surfaces may include a built -up membrane. No wood shingles are permitted. <br />Built up roofs and rooftops, which include equipment, piping, flashing, and other <br />items behind the parapet walls shall be periodically painted and maintained for <br />continuity of the roof appearance. <br />
The URL can be used to link to this page
Your browser does not support the video tag.