My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Ord 2015-021/Building and Building Regulations (Ch. 14 revisions and updates)
San-Marcos
>
City Clerk
>
02 Ordinances
>
2010's
>
2015
>
Ord 2015-021/Building and Building Regulations (Ch. 14 revisions and updates)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 9:18:23 AM
Creation date
7/10/2015 3:08:58 PM
Metadata
Fields
Template:
City Clerk
City Clerk - Document
Ordinances
Number
2015-21
Date
7/7/2015
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Withifl Si, -ht Of the Spa OF h0t tlih Thi -S requiFenient shall appl�, to single 4tmily Ekk,ellings as well as <br />(8) Portable or temporary project offices or trailers will be allowed to be wired in type NM, NMC, or NMS <br />cable during the construction phase of a project. However, the structure shall be removedrp for to wlen-a <br />certificate of occupancy is issued for the building under construction. <br />(9) Pre -manufactured portable offices or trailers are allowed to be wired in type NM, NMC or NMS cable, <br />provided they are used as temporary buildings only. To be so considered, they may not be placed on <br />permanent foundations or have the transport undercarriage removed or have the foundation enclosed to <br />give a permanent appearance. <br />(10) All services shall have disconnecting means located outside of the building served. <br />(11) Electrical metallic tubing (article 358) will not be installed in concrete. <br />(12) Overhead service entrance conductors shall be in rigid metal conduit, intermediate metal conduit, or <br />electrical metallic tubing. Service entrance cable (article 338) will not be authorized unless protected by <br />approved conduit. If the service entrance conduit is a service mast, only two-inch or larger rigid metal <br />conduit or intermediate metal conduit will be used. <br />(13) A minimum of one grounding conductor, sized according to the NEC, will be installed in any field -installed <br />electrical conduit. This requirement is in addition to those prescribed by article 250.64. <br />(14) Flexible metal conduit (article 348) will not be used in wet locations. <br />(15) Color coding of conductors. Color coding of conductors will be as follows, with the exception of control <br />circuits other than switches: <br />Single phase 120/240 volt wiring systems <br />A B N <br />Red Black White <br />Three phase four wire 120/208 volt wiring systems <br />A B C N <br />Red Black Blue White <br />Three phase three and four wire 120/240 volt delta wiring systems <br />Page 28 <br />
The URL can be used to link to this page
Your browser does not support the video tag.