My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Res 2009-039
San-Marcos
>
City Clerk
>
03 Resolutions
>
2000 s
>
2009
>
Res 2009-039
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/22/2009 2:05:07 PM
Creation date
4/8/2009 9:31:06 AM
Metadata
Fields
Template:
City Clerk
City Clerk - Document
Resolutions
City Clerk - Type
Agreement
Number
2009-39
Date
3/31/2009
Volume Book
180
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
9. Description of Facilities Owned by Each Party: <br />San Marcos Electric Utility owns: <br />• One (1) power transformer PWT-2, T-2 with associated foundation, surge arresters, <br />and protective relaying <br />• One (]) circuit switcher CS-8235 with bypass switch 8236. 138 kV transformer bus <br />with associated steel structures for PWT-2, 138 kV operating bus disconnect switches <br />8237 and 8238, and insulators <br />• Three (3) distribution bays including A-frames, trusses, insulators, disconnect <br />switches, surge arresters, 12.5 kV operating and transfer bus, and metering current <br />transformers for PWT-2, T-2 <br />• Five (5) distribution circuit breakers RW-220, RW-230, RW-240, RW-320, RW-340 <br />• Disconnect switches in distribution bays 1-0 and 1-4 <br />LCRA TSC owns: <br />The Redwood Substation including, but not limited to, the following items: <br />• One (1) 138 kV circuit switcher CS-19235 with bypass switch 19232 and disconnect <br />switches 19237 and 19238 <br />• One (1) power transformer PWT-3, T-3 with associated surge arresters <br />• Three (3) distribution and total bays including A-frames, trusses, insulators, <br />disconnect switches, surge arresters, 12.5 kV operating and transfer bus, bus <br />potential transformers and metering current transformers for PWT-3, T-3 <br />• One (1) total circuit breaker RW-330 <br />• Station Service equipment for PWT-3 <br />• 12.5 kV bus potential transformers for PWT-2, and PWT-3, and metering current <br />transformers <br />• Control house with station battery <br />10. Operational Responsibilities of Each Party: Each Parry will be responsible for the <br />operation of the equipment it owns. <br />11. Maintenance Responsibilities of Each Party: Each Party will be fully responsible for the <br />maintenance of the equipment it owns. <br />12. Other Terms and Conditions: The City and LCRA TSC are to share access to the <br />substation by LCRA TSC locks in the gate and in the control house doors. <br />LCRA TSC - San Marcos Electric Utility Page 28 of 35
The URL can be used to link to this page
Your browser does not support the video tag.