Res 2016-177/approving an amended and restated Interconnection Agreement with the LCRA Transmission Services Corporation (“LCRA TSC”) to, among other things, clarify the transmission and distribution functions of the parties, provide metering to be gover
San-Marcos
>
City Clerk
>
03 Resolutions
>
2010's
>
2016
>
Res 2016-177/approving an amended and restated Interconnection Agreement with the LCRA Transmission Services Corporation (“LCRA TSC”) to, among other things, clarify the transmission and distribution functions of the parties, provide metering to be gover
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2017 12:56:52 PM
Creation date
1/23/2017 1:06:35 PM
Metadata
Fields
Template:
City Clerk
City Clerk - Document
Resolutions
City Clerk - Type
Approving
Number
2016-177
Date
12/20/2016
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
FACILITY SCHEDULE NO. 2 <br />1. Name: Strahan Substation <br />2. Facility Location: The Loop 82/Strahan Substation is located at 709 Aquarena Springs <br />Dr. (Loop 82), San Marcos, Hays County, Texas. <br />3. Point of Interconnection: There is one (1) Point of Interconnection in the Strahan <br />Substation: where the 12.5 kV bus terminates at the power transformer T-1 LV bushings. <br />4. Transformation Services Provided by LCRA TSC: Yes, per separate Transformation <br />Service Agreement <br />5. Metering Services Provided by LCRA TSC: Yes, per separate Wholesale Metering <br />Service Agreement <br />6. Delivery Voltage: 12.5 kV <br />7. Metered Voltage and Location: The metered voltage is 12.5 kV. The metering current <br />transformers are located in T-1. The metering potential transfonners are located on the <br />12.5 kV operating bus. <br />8. One Line Diagram Attached: Yes <br />9. Description of Facilities Owned by Each Party: <br />San Marcos Electric Utilities owns: <br />• The site (property), including site work, fence, foundations, and ground grid <br />• Five (5)distribution circuit breakers ST -510, ST -520, ST -530, ST -550, ST -560 <br />• 15 kV (60:1 ratio) bus potential transformers <br />• Six (6) distribution and total bays including A -frames, trusses, insulators, <br />disconnect switches, surge arresters, 12.5 kV operating and transfer bus, bus <br />potential transformers and metering current transformers <br />• Control house with station battery <br />LCRA TSC owns: <br />• One (1) power transformer T-1 with associated surge arresters <br />• One (1) 138 kV circuit switcher CS -9515 with bypass switch 9517 and disconnect <br />switch 9512 <br />• Two (2) mobile transformer disconnect switches ST -582 and ST -585 on the ends <br />of the 12.5 IX operating and transfer buses <br />• Station Service equipment <br />10. Operational Responsibilities of Each Party: Each Party will be responsible for the <br />operation of the equipment it owns. <br />LCRA TSC — San Marcos Electric Utility First Amended IA Page 20 of 39 <br />