Laserfiche WebLink
insulators, disconnect switches, surge arresters, 12.5 kV operating and transfer <br />bus, and bus potential transformers <br />• Two (2) station service SS -1 and SS -2 <br />LCRA TSC owns: <br />The San Marcos Substation including, but not limited to, the following items: <br />• The site (property), including site work, fence, gravel, ground grid and other <br />appurtenances <br />• 13 8 kV operating and transfer bus <br />• One (1) 138 kV bus potential transformer PT -1 <br />• One (1) 138 kV bus differential and breaker failure relaying scheme <br />• Two (2) metering package <br />• One (1) 138 kV surge arrester SA -6 <br />• Underfrequency relay panel <br />• Control house and station battery <br />10. Operational Responsibilities of Each Party: Each Party will be responsible for the <br />operation of the equipment it owns. LCRA TSC shall operate the SMEU 138 kV <br />equipment, including monitoring the SMEU power transformer alarms. <br />11. Maintenance Responsibilities of Each Party: Each Party will be fully responsible for <br />the maintenance of the equipment it owns. <br />12. Other Terms and Conditions: <br />• The City and LCRA TSC are to share access to the substation by LCRA TSC <br />locks in the gate and in the control house doors. <br />• The City will supply and allow LCRA TSC use of its 12.5 kV bus potential <br />transformers PT -3 and PT -4 for metering. <br />• The City will supply and allow LCRA TSC use of transformer T-1 and T-2 <br />metering current transformers for its metering. <br />• The City will supply and allow LCRA TSC use of transformer T-1 and T-2 <br />relaying current transformers for LCRA TSC's bus differential & breaker failure <br />relaying scheme. <br />• The City will provide breaker failure initiate contacts from its circuit switchers <br />CS4975 and CS4985 relaying panel to LCRA TSC's bus differential & breaker <br />failure relaying panel. <br />• LCRA TSC will provide tripping and close inhibit contacts from its bus <br />differential & breaker failure relaying panel to City's circuit switchers CS4975 <br />and CS4985 relaying panels. <br />• LCRA TSC will provide City access to 125 VDC and 120 VAC power. Circuits <br />must have over current protection devices (OCPD) sized according to NEC <br />standards. Panel boards containing the OCPD may belong to either LCRA TSC <br />(if space is available) or City. <br />• The City will supply and allow LCRA TSC use of Station Service 41 and <br />Station Service #2 for primary and backup station power. <br />LCRA TSC — San Marcos Electric Utility Page 34 of 39 <br />