EXHIBIT A: SERVICES <br />Consultant will provide geotechnical engineering design services for the Project. The purpose of <br />this engagement will be to evaluate surface and subsurface conditions within the Project limits to <br />develop geotechnical parameters that may be used in the preparation of design guidelines and <br />specifications and construction documents for the planned Project. <br />A. PROJECT INFORMATION <br />Based on information provided to us, we understand that the Project will involve the design and <br />construction of a replacement wastewater line within the alignment of Columbia Avenue in San <br />Marcos, Texas. The line will be about 1,900 linear feet and run from Marlton Street on the north <br />and Prospect street on the south. Expected depth for the manholes on the wastewater line range <br />from 9 feet to 23 feet deep. <br />If any of the above information is not correct, please contact us so that we can make the necessary <br />modifications to this document. <br />B. SERVICES <br />Services to be provided by Drash will involve three segments of work: 1) Field, 2) Laboratory, and <br />3) Engineering. These segments are outlined herein. <br />Field <br />The field program will involve drilling 4 borings. Borings at intersections of Columbia Street and <br />Hazelton Street, Advance Street, Brown Street and Prospect Street will be drilled to 10 feet, 25 <br />feet, 20 feet, and 15 feet respectively. Drash will obtain right-of-way and lane closure permit and <br />on-site traffic control. Permits or waivers, if required, for drilling in the Edwards Aquifer Recharge <br />Zone will be the responsibility of Alan Plummer Associates, Inc. <br />Laboratory <br />The samples recovered during drilling of the borings will be tested in our laboratory to determine <br />their index and engineering characteristics. The laboratory tests will be performed in accordance <br />with applicable geotechnical industry standards. <br />Engineering and Report <br />Using the field and laboratory data collected for this project, geotechnical engineering analyses <br />will be performed to provide the following information: <br />Specifications for selection of construction materials to be used backfill. <br />• Specifications with regard to placement and compaction of general site materials, <br />pavement subgrade, fill areas, and backfill areas. <br />An engineering report will be prepared that will include the above information. The engineering <br />report will also include: <br />Boring location plan depicting the location of the borings drilled for the Project. <br />Drash Agreement No. PG 1161277 <br />Columbia Street 2 <br />Wastewater Line Replacement <br />San Marcos, Texas <br />11= rash <br />C0 NS 11LTNNTS <br />