Ord 2020-013/amending Chapter 38, Fire Prevention and Protection, of the San Marcos City Code by revising the local adoption of and amendments to the 2015 edition of the International Fire Code
San-Marcos
>
City Clerk
>
02 Ordinances
>
2020's
>
2020
>
Ord 2020-013/amending Chapter 38, Fire Prevention and Protection, of the San Marcos City Code by revising the local adoption of and amendments to the 2015 edition of the International Fire Code
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2020 1:25:32 PM
Creation date
4/28/2020 1:06:17 PM
Metadata
Fields
Template:
City Clerk
City Clerk - Document
Ordinances
City Clerk - Type
Amending
Number
2020-13
Date
4/7/2020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Section 901.4 change to read as follows: <br />901.4.7 Wall Mounted Document Box. A wall mounted document box shall be placed in fire <br />sprinkler riser rooms or at any fire alarm control unit. Documents stored in this box shall include <br />building floor plans, alarm plans, sprinkler plans and any other documents required by the fire <br />code official. <br />Section 901.6.3; add Sections 901.6.3 and 901.6.3.1 to read as follows: <br />901.6.3 False Alarms and Nuisance Alarms. False alarms and nuisance alarms shall not be given, <br />signaled or transmitted or caused or permitted to be given, signaled or transmitted in any manner. <br />901.6.3.1 False Alarm and Nuisance Alarm Penalty. The owner or manager of an occupancy in <br />which the fire alarm system signals or transmits more than three false alarms, as the result of a <br />mechanical, electrical, or component failure within the alarm system, in any rolling 12 -month <br />period shall be fined as follows for subsequent false or nuisance alarm beyond the third false or <br />nuisance alarm in the rolling 12 -month period: <br />a) Fourth false or nuisance alarm shall be fined at $500 <br />b) Fifth false or nuisance alarm shall be fined at $1,000 <br />c) Sixth and all subsequent false or nuisance alarms shall be fined at $1,500. <br />False alarms as the result of weather-related activation or false alarms caused by the initiation of <br />the alarm system by the activation of a manual pull station, or the activation by a person(s) <br />tampering with a detection or signaling device or component of the alarm system, shall not be <br />subject to penalty. <br />Section 903.2.9; add Section 903.2.9.3 to read as follows: <br />Section 901.8.2; change to read as follows: <br />901.8.2 Removal of existing occupant -use hose lines. The fire code official is authorized to permit <br />the removal of existing occupant -use hose lines and hose valves where all of the following <br />conditions exist: <br />1. Installation is not required by this code or the International Building Code. <br />2. The hose lineCss) would not be utilized by trained personnel or the fire department. <br />3. If the remaining outlets for occupant -use hose lines are removed, but the hose valves are <br />required to remain as per the fire code official, such valves shall be are compatible with <br />local fire department fittings. <br />903.2.9.3 Self -Service Storage Facility. An automatic sprinkler system shall be installed <br />throughout all self-service storage facilities. <br />Exception: One-story self -storage facilities that have no interior corridors. <br />