Res 2022-205R/Approving a contract with Firetrol protectionsystem inc. for prevantive maintanance and inspection of fire alarms.
San-Marcos
>
City Clerk
>
03 Resolutions
>
2020's
>
2022
>
Res 2022-205R/Approving a contract with Firetrol protectionsystem inc. for prevantive maintanance and inspection of fire alarms.
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2022 10:14:39 AM
Creation date
10/30/2022 8:50:16 PM
Metadata
Fields
Template:
City Clerk
City Clerk - Document
Resolutions
City Clerk - Type
Contract
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
FIRETR <br />OL <br />%*,boodle' z Protection Systems <br />.'Vprvirp Ratpv <br />Fire Alarm: $100.00 Hr Straight Time $150.00 Hr Overtime <br />Sprinkler: $100.00 Hr Straight Time $150.00 Hr Overtime <br />Gas Systems/ Hoods: $100.00 Hr Straight Time $150.00 Hr Overtime <br />Straight time is Monday — Friday 7.40am to 4; 00pnx <br />• 2 lir minimum applied to all service calls <br />INSPECTION PROCEDURES <br />Fire Sprinider Systems <br />Fire Sprinkler systems will be inspected in accordance with the manufacturer's guidelines, N.F.P.A Standard 25, and the local Authority Having <br />Jurisdiction (AHJ). Inspections will be conducted quarterly or annually as required by the local AHJ and at a minimum annually and every five <br />years. Annual inspection procedures of sprinkler systems include: <br />• Inspect the fire department connections(s) to ensure caps/plugs are in place, coupling/swivels are undamaged, gaskets are present, signs are <br />in place and no obstruction or damage is present. <br />• Inspect the riser for any water leaks, ensure bracing is intact, and alarm valves are in proper position and no obstructions or damage is <br />present. <br />• Inspect gauges for damage and ensure the three-way test valve is present and open. <br />■ Inspect and test water flow alarm bell/gong for any visual obstructions and note if the fire sprinkler system is monitored. <br />• Inspect that the control valves are secure, with no leaks, the open/shut indicators are working, and no obstructions or damage is present. <br />■ Inspect fire sprinkler heads for leaks, paint, or corrosion or flow obstruction; portion and check that the required sprinkler heads and <br />wrench are on site. <br />• Inspect main drain test for static psi before, residual psi during and static psi after test completion. <br />• Any defect found will be noted and sent to appropriate person with a cost quotation for repairs and re-certif cation. <br />Fire Pumps <br />Inspections will be in accordance with manufacturer's guidelines, N.F.P.A Standard 25, and the local Authority Having Jurisdiction (AHJ). <br />Inspection procedures of fire pumps include: <br />■ Type of Driver Diesel or Electric. <br />• Check Rating, GPM, and PSI. <br />• Check and verify pump and motor are very on damage and leaks. <br />• Verify all hoses and batteries and free of corrosion and cracks. <br />■ Shut and open all fire pump valves to insure proper operation. <br />• Check auto start and stop by flow test. <br />• Conduct load and non load test and graph to ensure proper operation as designed. <br />• Check water tank and floats for proper operation. <br />• Verify all lights and gauges are working properly. <br />• Verify pump and controller SIN and Manufacture information. <br />• Any defect found will be noted and sent to the appropriate person with a cost quotation for repairs and re -certification. <br />4 <br />4616 W. Howard Ln, Bldg. 7, Suite 700 Austin, TX 78725 Main (512) 687-0115 Fax (512) 687-4120 www.firetrol.net <br />FIRE PROTECTION AND LIFE SAFETY SPECIALISTS <br />TX. Licenses: Sprinkler # SCR -G-42921 Extinguisher # ECR -17514321 Fire # AGR -17511681 Alarm B13372 <br />