Res 2022-205R/Approving a contract with Firetrol protectionsystem inc. for prevantive maintanance and inspection of fire alarms.
San-Marcos
>
City Clerk
>
03 Resolutions
>
2020's
>
2022
>
Res 2022-205R/Approving a contract with Firetrol protectionsystem inc. for prevantive maintanance and inspection of fire alarms.
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2022 10:14:39 AM
Creation date
10/30/2022 8:50:16 PM
Metadata
Fields
Template:
City Clerk
City Clerk - Document
Resolutions
City Clerk - Type
Contract
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
••••••! FIRETROL <br />Protection Systems <br />Fire Hose and Standpipe & Hydrants <br />Inspections on this equipment will be in accordance with N.F.P.A. Standard 1962 and Standard 14, the manufacturer's guidelines, and the local <br />Authority Having Jurisdiction (AHJ). Inspections will be annually unless otherwise noted. Annual inspection procedures include: <br />• Inspection of the hose, couplings and nozzles to insure they are free from debris, mildew and rot. Verify that there is no damage caused by <br />chemicals, burns, cuts, abrasions or vermin. <br />• Inspect the interior linear at each end for any physical signs of linear delarninating. <br />Inspect the hoses for the current test psi. <br />• Ensure the location of the hose is sufficient and verify it is not blocked. <br />• Verify the manufacture date of each hose and perform hydrostatic testing as required every 5 years from same and then every 3 years <br />thereafter. <br />Flow Hydrants for proper flow and pressure. <br />• Any defect found will be noted and sent to appropriate person with a cost quotation for repairs and re -certification. <br />Backflow Prevention Devices <br />Backflow Prevention devices are to be serviced annually per Title 22 Health Code, Universal Plumbing Code and the local Authority Having <br />Jurisdiction (AHJ). When required a licensed plumber will conduct testing, <br />_Fire Alarm Systems <br />Fire Alarm systems will be inspected in accordance with N.F.P.A Standard 72, the local Authority Raving Jurisdiction (AHJ) and the manufacturer's <br />guidelines. CFP will conduct quarterly or semi annual inspections as required by the local Authority Having Jurisdiction (AHJ) and at a minimum <br />will perform annual inspections. Annual inspection procedures of fire alarm systems include: <br />• A complete inspection of the fire alarm system control panels), <br />• Inspection to ensure proper zone operation. <br />• Inspect: all manual pull stations and ensure they are accessible. <br />• Inspect smoke detectors and magnetic hold open devices. <br />• Inspect supervisory devices and ensure they are sending supervisory signals, <br />• Inspect heat detectors. <br />• Inspect and test audible alarm bells. <br />• Inspect and test area smoke detectors. <br />■ Inspect and confirm that the systems power supplies including battery back ups are functioning. <br />• If the system is monitored, ensure that a signal was received at the central station. <br />Any defect found will be noted and sent to appropriate person with a cost quotation for repairs and re-certif cation. <br />• Current fire codes insist that every other year smoke detection devices must have a sensitivity test in addition to the inspection. <br />Fire Extinguishers <br />Inspections will be in accordance with the manufacturer's guidelines, N.F.P.A Standard 10, and the local Authority Having Jurisdiction (AHJ). <br />Inspections will be annually unless otherwise noted. Annual inspection procedures of fire extinguishers include: <br />• Visually inspect extinguisher. <br />• Inspect last hydrostatic test date (12 years) and last 6 -year maintenance inspection. <br />• Inspect pressure gauge. <br />• Inspect shell, valve and discharge hose for damage or corrosion. <br />• Inspect carry handle and push lever for functionality. <br />• Install new tamper seal. <br />• Clean shell and install certification tag, <br />• Any defect found will be noted and sent to appropriate person with a cost quotation for repairs and re -certification. <br />4616 W. Howard Ln, Bldg. 7, Suite 700 Austin, TX 78728 Main (512) 687-01.1.5 Fax (512) 687-0120 www.firetrol.net <br />FIRE PROTECTION AND LIFE SAFETY SPECIALISTS <br />TX. Licenses: Sprinkler # SCR -G-02921 Extinguisher # ECR -17514321 Fire # ACR. -17511581 Alarm B13372 <br />