Laserfiche WebLink
<br />180-w <br /> <br />2. Intersecting Utility Easements, Where two utility <br />easements intersect or turn at a right angle, a cutoff <br />of not less than ten feet (10') from the normal inter- <br />section of the easement line shall be proJl'id.ed along <br />each easement line. <br /> <br />3. Curb. Normal curb exposure shall be required where <br />utility easements intersect streets, <br /> <br />4, <br /> <br />Overhang Easements, Overhang easements of at least <br />four feet (4') on each side of the twenty foot (20') <br />easement strip, at a height at or above eighteen <br />feet (lS'), shall be provided in all utility easements, <br /> <br />5, <br /> <br />Guy Wire Easement, Where utility easements are not them~ <br />selves straight within each block, or if the same do not <br />connect on a straight course with the utility easements <br />of adjoining blocks, then an additional easement shall <br />be provided for the placing of guy wires on lot division <br />lines in order to support poles set on curving or deviating <br />rights-of-way or alleys. <br /> <br />I <br /> <br />Section E. <br /> <br />Sidewalks. <br /> <br />Sidewalks shall be constructed by the subdivider in <br />accordance with City standards and specifications as follows: <br /> <br />1, On the subdivision side, or sides, of all major thorough- <br />fares or arterial streets; <br /> <br />2. On both sides of a street that serves as a secondary or <br />collector street, or as an approach to a school, bus <br />stop, shopping center, or focal point of the community, <br />or where density exceeds six (6) families per net acre; <br /> <br />3. <br /> <br />On at least one side of all marginal access streets; and <br /> <br />I <br /> <br />4. <br /> <br />As deemed necessary by the Commission in commercial, <br />industrial, public grounds, and multi-family dwelling <br />areas. <br /> <br />Sidewalks shall not be required in areas of open development, <br />or where all lots have a one hundred fifty foot (ISO') frontage <br />or more. <br /> <br />Section F, <br /> <br />Crosswalk Ways. <br /> <br />Crosswalk ways six feet (6') in width shall be dedicated where <br />deemed necessary by the Commission to provide circulation or access <br />to schools, playgrounds, shopping centers, transportation, and <br />community facilities, or to provide pedestrian circulation within <br />the subdivision, Crosswalk ways shall be provided with a concrete <br />sidewalk six feet (6') wide, <br /> <br />Section G, <br /> <br />Water, Sewer, and Drainage Facilities. <br /> <br />The subdivider shall, at his own cost, dedicate such right- <br />of-way and construct such water mains, water lines, sanitary <br />sewers, storm sewers, and drainage ditches of such a size as to <br />adequately serve the area being subdivided, as determined by the <br />Commission. All facilities shall be constructed in accordance <br />with City standards, <br /> <br />I <br /> <br />In all subdivision developments, dwelling units (single <br />family, duplexes, townhouses, multi-family, apartments, condo- <br />miniums, and cluster developments) shall be connected to sanitary <br />sewer mains by approved sewer lines, except where septic tanks <br />are approved by the Commission. <br />