My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Ord 2002-018
San-Marcos
>
City Clerk
>
02 Ordinances
>
2000 s
>
2002
>
Ord 2002-018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2006 9:45:43 AM
Creation date
6/23/2006 9:45:23 AM
Metadata
Fields
Template:
City Clerk
City Clerk - Document
Ordinances
City Clerk - Type
Revising
Number
2002-18
Date
3/4/2002
Volume Book
146
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />(a) All buildings classified as Group B, Group S-2, or Group F-2 having a fire area <br />exceeding 20,000 sq. ft. <br /> <br />Exception: If there is a conflict between this section and other sections of this code, <br />the most restrictive requirement shall apply. <br /> <br />(b) Any building constructed after April 1, 2002 that exceeds 20,000 sq. ft. or any <br />attached construction, alteration, or addition to an existing structure of any group that <br />causes the structure to exceed 20,000 sq. ft. For purposes of tills section, an automatic <br />fire sprinkler system is to be installed in the non-conforming or existing structure in <br />addition to the new construction area. <br /> <br />Section 903.2.7, exception 1, is amended to read as follows: <br /> <br />1. Where guest rooms are not more than two stories above the lowest level of the exit <br />discharge, each guest room has at least one door leading directly to the exterior, and <br />the fire area is less than 12.000 sq. ft. <br /> <br />Section 903.2.8 is amended to read as follows: <br /> <br />903.2.8. Group R-2. An automatic fire sprinkler system shall be provided throughout <br />all buildings with a Group R-2 fire area more than two stories in height, including <br />basements, or having more than 16 dwelling units, or having a fire area that exceeds <br />12,000 sq. ft. <br /> <br />Section 903.2.9 is amended to read as follows: <br /> <br />903.2.9. Group R-4. An automatic fire sprinkler system shall be provided throughout <br />all buildings with a Group R-4 fire area with more than eight occupants or a fire area <br />that exceeds 12,000 sq. ft. <br /> <br />Section 2411.4 is amended to read as follows: <br /> <br />241104. Operations such as the warming of foods, cooking demonstrations, and <br />similar operations that use solid flammables, butane, or other similar devices which <br />do not pose an ignition hazard may be approved. <br /> <br />Section 3301.1.3, exception 4, is deleted. <br /> <br />Chapter 45 is amended as follows: <br /> <br />Any reference to NFPA 13-96, 13D-96, or 13R-96 is amended to NFPA 13-94, 13D- <br />94, and 13R-94. <br /> <br />C:\TEMP\mark's tire code 2-6-02.doc <br /> <br />- 10 - <br />
The URL can be used to link to this page
Your browser does not support the video tag.