Laserfiche WebLink
<br />-17- <br /> <br />normal expiration date, the licensee must pay all <br />license fees and/or post all surety bonds pursuant <br />to other provisions of this code in order to <br />receive a valid license to continue electrical <br />work. <br /> <br />Sec. 9-6.5. Right of appeal. <br /> <br />Any person denied a license or whose license <br />has been suspended by the Electrical Board, except <br />where such cancellation or suspension is automatic <br />under the provisions of this chapter, shall have <br />the right to file a petition within ten days of the <br />date of the denial or suspension for a hearing <br />before tne Municipal Court Judge. The Court Clerk <br />shall set the matter for hearing with no less than <br />ten (10) days written notice to the aggrieved <br />person of the date of the hearing. The Judge shall <br />take testimony and examine the facts of the case, <br />and determine whether or not there was substantial <br />evidence to support the decision of the Board under <br />the provisions of this chapter. <br /> <br />Sec. 9-7. <br /> <br />Amendments to the national electrical <br />code. <br /> <br />The following rules shall take precedence over <br />and supercede any portion of the NEC where <br />conflicts occur: <br /> <br />(a) The following minimum wire sizes shall be <br />used for the type of circuit indicated: <br /> <br />No branch circuit shall have wire smaller <br />than #12 AWG. This does not prohibit <br />smaller wire sizes for circuits 90 volts <br />and lower, nor for control circuits. <br />Built-in ovens shall have a minimum wire <br />size of #10 AWG copper. <br />Ranges shall have a minimum wire size of <br />#8 AWG copper, or equivalent aluminum. <br />Window air conditioners shall have a <br />minimum wire size of #10 AWG copper. <br />Water heaters shall have a minimum wire <br />size of #10 AWG copper. <br /> <br />(b) No aluminum wire shall be used smaller <br />than # 6 AWG. <br /> <br />(1) <br /> <br />(2) <br />(3) <br /> <br />(4) <br />(5) <br /> <br />(c) <br /> <br />No copperclad wire shall be permitted. <br /> <br />(d) Certain wiring methods permitted under <br />the NEC shall not be allowed (except where existing <br />prior to adoption of this code), specifically: <br /> <br />(1) <br />(2) <br />(3) <br />(4) <br /> <br />Article 320 - Open Wire On Insulators <br />Article 324 Concealed Knob-and-Tube <br />Wiring <br />Article 333 - Armored Cable <br />Article 334 Metal-Clad Cable (this <br />prohibits interlocking tape and <br />corrugated tube versions of MC cable, but <br />permits the smooth tube version.) <br /> <br />(e) Nonmetallic-sheathed Cable (Article 336) <br />and shielded nonmetallic-sheathed cable (Article <br />337) shall be permitted to be used only in <br />dwellings, as defined in Article 100. It <br />specifically shall not be used in hotels, motels, <br />rooming houses, fraternity or sorority houses. <br />