My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Ord 1987-020
San-Marcos
>
City Clerk
>
02 Ordinances
>
1980 s
>
1987
>
Ord 1987-020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/15/2007 2:20:39 PM
Creation date
8/15/2007 2:20:39 PM
Metadata
Fields
Template:
City Clerk
City Clerk - Document
Ordinances
City Clerk - Type
Agreement
Number
1987-20
Date
2/9/1987
Volume Book
86
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />In phase III two additional 1,000,000 gallon storage tanks should <br />be constructed, one at the proposed Well Site A and one near the <br />standpipe in the Lo\,;'1Ilans' Ranch development, to supply a portion <br />of the required storage for the lower pressure plane through the <br />year 2005. These additions should upgrade the system to <br />adequately supply the entire basin with ground storage and the <br />lower pressure plane with elevated storage through the year 2005. <br />An additional 100,000 gallon elevated storage tank should also be <br />constructed in phase III in the upper pressure plane to provide <br />the upper pressure plane with the required elevated storage for <br />the projected 2005 population. <br /> <br />E. <br /> <br />Pumping <br /> <br />Recommended guidelines for water service pumps are to size the <br />pumps to handle 80% of the firm maximum hour demand flow. Two <br />locations are proposed to supply pumping for the basin. Pumping <br />"..ill be required in the LJwmans' Ranch development to supply the <br />elevated storage tank for the upper upper pressure plane, as well <br />as to augment the up:¡:er pressure plane demand flow. The <br />remainder of the pumping facilities are proposed to be located at <br />Well Site A to supply the elevated tank in the upper pressure <br />plane as well as high demand service for the lower pressure plane. <br /> <br />TABLE 7 <br />Pumping Capacity <br /> <br />Design Phase <br />Phase I <br />Phase II <br />Phase III <br /> <br />Total <br />Firm Pumping Capacity <br />(gpm) <br />0 <br />1500 <br />3000 <br /> <br />Initially there is no need for pumping because the standpipe in the <br />Lowmans' Ranch development \'oill adequately service the area <br /> <br />JONES ð: NEUSE <br /> <br /> <br />I <br />) <br /> <br />27 <br />
The URL can be used to link to this page
Your browser does not support the video tag.