My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Res 2014-050/Transmission Planning Data Services Agreement with ERCOT and LCRA
San-Marcos
>
City Clerk
>
03 Resolutions
>
2010's
>
2014
>
Res 2014-050/Transmission Planning Data Services Agreement with ERCOT and LCRA
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/22/2015 3:44:17 PM
Creation date
4/22/2014 8:46:40 AM
Metadata
Fields
Template:
City Clerk
City Clerk - Document
Resolutions
City Clerk - Type
Approving
Number
2014-50
Date
4/15/2014
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Handbook for Planning Data Services <br />5. ERCOT Power Flow Base Planning Cases (Data Set A and Data Set B) <br />Description: <br />Make available Owner transmission facility data required for updating the ERCOT <br />power flow cases. Section 6.1 of the ERCOT Planning Guide states: "Each TSP, or its <br />Designated Agent, shall provide its respective transmission network steady -state model <br />data, including load data. To meet the requirements of Section 6.1, LCRA and Owners <br />will perform the following: <br />Owner Shall: <br />1. Provide facility data to LCRA required by ERCOT. This includes but is not limited to: <br />transmission line parameters /characteristics, autotransformer data, station <br />location /bus configuration, facility ratings, and switching device ratings. I ne <br />parameters / characteristics and other data provided by the Owner shall be in the <br />following formats. <br />Transmission line parameters /characteristics: <br />liV, <br />From Station <br />To Station <br />R <br />K <br />B <br />Rate A <br />Rate B <br />Rate l3 <br />a Len <br />8.719 <br />138 <br />Lockhart <br />Mendoza <br />0.00682 <br />0.03560 <br />0.01051 <br />220 <br />220 <br />220 <br />9.32 <br />!Vole: Minimum o-aigit preuislun requlruct Vr weauy ar w rr ruuci n, n, at 1U u va.uoa. <br />Autotransformer data: <br />High -side (H) winding rated voltage <br />138 <br />kV <br />Low -side (L) winding rated voltage <br />69 <br />kV <br />Tertiary (T) winding rated voltage <br />13.2 <br />kV <br />Winding leakage impedance HA <br />8.719 <br />% <br />(3- Phase) base MVA for H -L <br />36 <br />MVA <br />(3- Phase) load losses between H -L <br />78,038 <br />W <br />Winding leakage impedance H -T <br />13.389 <br />% <br />(3- Phase) base MVA for H -T <br />12.6 <br />MVA <br />(3- Phase) load losses between H -T <br />39,098 <br />W <br />Winding leakage impedance L -T <br />9.478 <br />% <br />(3- Phase) base MVA for L -T <br />12.6 <br />MVA <br />(3- Phase) load losses between L T <br />38,719 <br />W <br />Note: Information available on autotranstormer manufacturer test report. <br />7 I Pag, Rev. 0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.