Laserfiche WebLink
EROSION CONTROL <br />11. Containment - It is unlawful for any general contractor, subcontractor or owner to <br />permit, or cause to be permitted, erosion of material from a construction site. Certain <br />erosion control measures identified by the City of San Marcos are to be employed to <br />prevent erosion, however, these are only minimum standards. In the event of unusual <br />site conditions, or weather related events, more stringent requirements may be required <br />(on -site or off) to maintain erosion control. The owner or his representative is responsible <br />for all changes, upgrades and continued maintenance of all erosion control features at <br />all times. <br />12. Inspection - Erosion control measures will be inspected by the City of San Marcos <br />prior to and during the construction process: <br />Public <br />The Department of Engineering is responsible for the inspection of <br />public works projects. <br />Commercial construction larger than residential three -plex. <br />Private <br />- The Building Deportment is responsible for the inspection of all <br />residential construction up to residential three -plex. <br />13. Notes - Containment <br />- All designs to prevent the erosion of soil and debris from the <br />construction site or surrounding areas damaged by construction <br />shall be maintained by the contractor during construction. <br />C - Site work, permitted by the Site Development Permit, cannot begin <br />0 until erosion control measures are in place, including silt fence, <br />construction entrance, rock berms and tree protection, as shown in <br />the plans. <br />Ln <br />1 - Storm drain inlets within 200 foot of any permitted construction <br />0 area must be protected per detail provided by the city. <br />z <br />x <br />ZJ - The contractor or owner must have a designated person responsible for <br />monitoring erosion control measures to insure that all federal, state, <br />& local laws and regulations are being complied with. This person shall <br />o be responsible for all required forms and documentation to meet regulations <br />C of the EPA, NPDES, TPDES general permit. <br />�o <br />v If a critical environmental feature or cavern is discovered during <br />'o construction the Environmental & Engineering inspector shall be notified. <br />C <br />0 <br />Y - All installed pipe will have letters /numbers at the 12:00 positions when <br />3 installed. <br />v <br />'a WATER UTILITY NOTES <br />m <br />°y 14. Definitions <br />C <br />.0 <br />Public utility line - Underground water line in a public right -of -way or easement <br />and the line is owned and maintained by the City of Son Marcos <br />to <br />/ <br />a. Private utility line - Underground water line on private property and the line is <br />E owned and maintained by the property owner (usually will have private water <br />o hydrants) <br />u <br />Combination utility water Line - That part of a water line that is for use on <br />a private property for potable water supply and /or water hydrants and /or fire <br />o suppression systems attached <br />U <br />Fire line - That <br />portion of a water line that is for the specific use of a fire <br />a suppression system (this does not typically include water hydrants) <br />3 <br />w <br />:? Domestic water line - That port of a water line that is for use on private property <br />for potable water supply (usually to a building) <br />C <br />0 Irrigation water line - That part of a water line that is for use on private property <br />o for irrigation only <br />15. Review - All utility plans are to be reviewed by Engineering, Building, Fire and <br />Water-Wostewater Departments. All utility lines on public and private property are to <br />a meet city standard as distributed by the Department of Engineering. The owner, <br />U) M <br />contractor or representatives are responsible for complying with all local, state and <br />U federal laws rules and ordinances. This statement of review does not authorize any <br />L 0' violations of standards, ordinances or laws of the City of San Marcos. No code violations <br />E o listed in this plan, or otherwise installed, manufactured or built, are "approved" by this <br />C ,_ office. <br />0 <br />in <br />0 m <br />0 0 <br />.o <br />Q N <br />O N <br />P <br />w w ILL � <br />16. Required Equipment - All taps to the city water system for private property shall be <br />metered or indicated. Accepted metering devices can be obtained by the Water - <br />Wastewater Utility. All metering devices and indicators shall be located on public right -of- <br />way or easement. All meters (including fire line low flow detector checks) must be made <br />assessable to city personnel at all times. All utility lines leading to private property <br />(except some authorized small domestic water lines) shall be provided with, at the <br />minimum, a testable, double check, back flow prevention device approved by the <br />AWWA. The back flow prevention device must be located as close as possible to the <br />public right -of -way on private property. Indicators, (attached to back flow prevention) <br />where specifically authorized for low flow measurement of water, must be located in an <br />easement authorized by the owner, but in all cases, be located on private property. Any <br />bypass device to a public water ( including indicators, service lines) supply must have, at <br />the minimum, a testable, double check, bock flow prevention device approved by the <br />AWWA. It is the responsibility of the owner and contractor to verify the type and size of <br />the back flow prevention device with the water purveyor, for the property served, prior to <br />construction. <br />All multifamily, condominium, apartment, manufactured home community, multiple home <br />community, multiple use facility or any other multi - family residence, must provide for the <br />quon 1 y o wo er o e measure In ivi ua me ers n occor once with state ow, Rule — <br />291.121 - 291.127, of the Utility Regulation TCEO (formerly the TNRCC). <br />Accepted Metering Devices <br />IRRIGATION METERS: SENSUS W- 160DRS TURBO -METER WITH BUILT IN STRAINER <br />COMMERCIAL DOMESTIC METERS: SENSUS SINGLE REGISTER COMPOUND METER AND STRAINER <br />WITH BYPASS <br />UTILITY LINE \COMBO METERS: SENSUS FIRE SERVICE ASSEMBLIES WITH BYPASS - SIZE 8" AND 10" <br />LINES ONLY. <br />RESIDENTIAL DOMESTIC METERS: 5/8 X 3/4 SENSUS METER (TYPICAL SIZE) <br />RESIDENTIAL IRRIGATION METERS: FULL 3/4" OR 1" SENSUS METER <br />Note: a bockflow prevention device with a low flow indicator can be utilized for fire <br />lines when authorized by the water - wastewater department (i.e. dedicated fire line <br />or privatelwater (fire) hydrant] utility line) <br />Accepted Utility Line Types (verify use with Department of Engineering) <br />C - 900 DR 14 CLASS 200 4" or larger (8" water main minimum required for utility service <br />on private property) <br />CLASS 50 DUCTILE IRON (class 50 required for water (fire) hydrant lead in) <br />SCHEDUAL 40 required on all private on -site domestic water lines (Building Department <br />Local Addendum to National Code) <br />Accepted water (fire) hydrants: <br />AMERICAN FLOW CONTROL 8848 <br />MUELLER COMPANY, SUPR CENTURION 250 <br />KLOW <br />Note: All fire hydrant threads to meet City of San Marcos Specifications (2112" & 41/2 <br />exterior thread - N5T) <br />17. Inspection - All water lines are to be tested P 200 psi for 10 minutes and 150 psi <br />for 1 hour. A fire line dedicated for a fire protection system shall be tested 0 200 psi for <br />2 hrs. Note: A licensed underground installer certified by the Texas Commission <br />on Fire Protection must perform underground fire line installation (Fire Sprinkler <br />System). Most plumbers and utility contractors do not meet these criteria! Please verify <br />before construction. City to be given 48 -hour notice (required) prior to all testing of utility <br />lines. City inspection required for all utility lines. <br />Public <br />- All utility taps, line installations, extensions, or adaptations in a <br />Public right -of way, up to and including the metering device, will be <br />inspected by the Engineering Department. <br />Private <br />- All utility tops, domestic water line installations, extensions, or <br />adaptations on private property, beyond the meter (including back <br />flow prevention) will be inspected by the Building Department. <br />- Water utility lines 4" and larger, utilized by any fire protection <br />system (fire line), or utility combo line will be inspected by the Fire <br />Marshals Office. <br />18. Tests - All bock flow prevention devices must be inspected by a State <br />licensed /certified back flow prevention assembly tester. All testers submitting inspection <br />results must be registered by the Son Marcos Water & Wastewater Utility Department. A <br />copy of the results are to be submitted to the City of San Marcos Water - Wastewater <br />Utility prior to activation of water service on a form prescribed by the utility. A copy of this <br />inspection is to be attached to the back flow prevention device that was inspected (leave <br />in meter box) . All water lines leading to private property must provide a bacteriological <br />test to the inspector noted in the inspections section above. <br />Water - Wastewater utility - 512 393 -8010 <br />Building Inspection - 512 393 -8240 <br />Engineering Department - 512- 393 -8130 <br />Fire Marshal /Inspections - 512 393 -8470 <br />E OF <br />*JOHN G. FRIED <br />MAN <br />I�,�......$848i : <br />'Ll1110 (011' <br />kIotz4l1 associates <br />CITY OF SAN. MARCOS <br />SAN MARCOS SIDEWALK PROJECT <br />GUADALUPE STREET - SIDEWALK <br />GENERAL NOTES <br />2 OF 4 <br />KLOTZ ASSOCIATES INC. PROJECT NO. SN E <br />N0. <br />0564.002. 000 2b <br />STATE CWNTY <br />TEXAS HAYS <br />OF SAN MARCOS REFERENCE NMBER HIGHWAY W. <br />REP 26 -001 1 LOOP 82 <br />