Laserfiche WebLink
1.3.3 Train City personnel in the use of EkaNetTM Network Manager and EkaNetTM Data <br />Manager. <br />1.3.4 Confirm System acceptance criteria for both Phase 1 -Alpha and Beta services with <br />appropriate City personnel. <br />1.3.5 Prepare for and participate in meetings with the City as requested including but not <br />limited to: <br />a) Prepare deployment planning and strategy; <br />b) Attend future-state business process design meetings with the City and the City's <br />Consultant, Utiliworks; <br />c) Identify required reports; <br />d) Identify input and output data file layout requirements; <br />e) Identify specifications for software development (reports, alarms, events); <br />f) Identify meter and network component installation procedures; <br />g) Develop new meter installation procedures (Harris System, EkaNetTM Data <br />Manager) including additional AMI network components installation procedures; <br />h) Assist City in planning of Gateway installation; <br />i) Design and Approve Gateway and Relay installation locations; <br />j) Provide Gateway and Relay mounting requirements; and <br />k) Plan Gateway communications backhaul (modem types, communications <br />network type/protocol, physical connection of devices, power requirements) <br />1.3.6 Perform specific pre-installation, technical services related to the Alpha/Beta Pilot as <br />follows: <br />a) Perform a RF propagation study on site and collect data for analysis in order to <br />develop plan(s) for Gateway and Relay installation. <br />b) Provide recommended server and configuration specifications to accommodate <br />EkaNetTM Network Manager and EkaNetTM Data Manager within seven calendar <br />days of the date set forth in Section 1.1. <br />c) Install EkaNetTM Network Manager and EkaNetTM Data Manager Software <br />applications on City servers. <br />d) Perform system training related to all Eka system components <br />e) Train appropriate City personnel on EkaNetTM Network Manager and EkaNetTM <br />Data Manager sufficiently in order that the City can operate the System and use <br />data (see Attachment D - Sample Eka Systems Installation and Training <br />Manual"). <br />1.3.7 Provide on-site Project management and technical services as follows: <br />A. Related to execution of the Alpha Test as follows: <br />1) Assist in the installation of two Gateways and associated Relays for <br />approved Alpha sites. For Gateway and Relay installation, the City will <br />provide personnel qualified to work in the communications space as <br />Advanced Metering Infrastructure Agreement Page 6 <br />