<br />Sees. 14.027-14.040. Reserved. <br /> <br />ARTICLE 3. RESIDENTIAL CODE FOR ONE AND TWO-FAMILY DWELLINGS <br /> <br />Sec. 14.041. Amendments. <br /> <br />The International Residential Code for One and Two-Family Dwellings, adopted in section 14.002, <br />is amended as follows: <br /> <br />R103 is deleted. <br /> <br />R104.7 is deleted. <br /> <br />R112 is deleted. <br /> <br />R905. 7 and R905.8 are deleted and replaced with the following: <br /> <br />R905.7. Wood shingles and shakes are prohibited as new or replacement roofing material <br />except that wood shingles and shakes as the primary roofing surface in existence on January <br />1, 2001, may be replaced with UL listed fire retardant shingles or shakes that are approved by <br />the fire marshal. <br /> <br />R905.10 is amended by adding the following: <br /> <br />R905.1 0.1.1. Any metal roof covering, gauge 26 or lighter, shall be installed over a solid deck <br />sheathing. <br /> <br />Sees. 14.042--14.075. Reserved. <br /> <br />ARTICLE 5. MECHANICAL CODE <br /> <br />Sec. 14.076. Amendments. <br /> <br />The mechanical code adopted by section 14.002 is amended as follows: <br /> <br />103 is deleted. <br /> <br />104.8 is deleted. <br /> <br />109 is deleted. <br /> <br />604.1 is amended to read as follows: <br /> <br />604.1. General. Duct insulation shall conform to the requirements of Sections 604.2 through <br />604.11 and the International Energy Conservation Code. However, in no case will the <br />minimum duct insulation value be less than R6. <br /> <br />C:\TEMP\bldg code 2-13-02 inc. doc <br /> <br />10 <br />