My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Ord 2002-020
San-Marcos
>
City Clerk
>
02 Ordinances
>
2000 s
>
2002
>
Ord 2002-020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/2/2008 1:40:55 PM
Creation date
6/23/2006 9:50:11 AM
Metadata
Fields
Template:
City Clerk
City Clerk - Document
Ordinances
City Clerk - Type
Code of Ordinances
Number
2002-20
Date
3/4/2002
Volume Book
146
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />903.2.8 Group R-2. An automatic sprinkler system shall be provided throughout all buildings <br />with a Group R-2 fire area which are more than two stories in height, including basements, or <br />which have more than 16 dwelling units, or which have a fire area that exceeds 12,000 sq. ft. <br /> <br />903.2.9 is deleted and replaced with the following: <br /> <br />903.2.9 Group R-4. An automatic sprinkler system shall be provided throughout all buildings <br />with Group R-4 fire area which have more than eight occupants or which have a fire area that <br />exceeds 12,000 sq. ft. <br /> <br />903.2.16 is added to read as follows: <br /> <br />903.2.16. Other occupancy classifications. An automatic sprinkler system shall be provided <br />throughout all buildings classified as Group B, Group F-2, or Group S-2 having a fire area <br />exceeding 18,000 square feet. <br /> <br />1507. 8 and 1507. 9 are deleted and replaced with the following: <br /> <br />1507.8. Wood shingles and shakes are prohibited as new or replacement roofing material, <br />except that wood shingles and shakes as the primary roofing surface in existence on January <br />1, 2001 may be replaced with UL listed fire retardant shingles or shakes that are approved by <br />the fire marshal. <br /> <br />Chapter 30 is amended to read as follows: <br /> <br />If there is a conflict between state law or the International Building Code, the most restrictive <br />provision shall apply. <br /> <br />3305.1 is amended to read as follows <br /> <br />3305.1. Sanitary facilities shall be provided during construction, remodeling, or demolition <br />activities in accordance with the International Plumbing Code. <br /> <br />3305.2 Contractors shall ensure that every construction, remodel, repair, or renovation site has <br />a method of containment for trash and debris. The contractor shall ensure that the trash and <br />debris is removed from the site on a regular basis so that the site is maintained in a clean, <br />sanitary, and safe condition at all times. <br /> <br />3305.3 Contractors shall ensure that every construction, remodel, repair, or renovation site has <br />adequate sanitary facilities for all workers. The contractor shall ensure that these facilities are <br />kept in a clean and sanitary condition at all times. <br /> <br />Chapter 35 is amended to read as follows: <br /> <br />Any reference to NFPA 13-96, 13D-96, or 13R-96 in Referenced Standards, NFPA, p. 693, <br />is amended to NFPA 13-94, 13D-94, and 13R-94. <br /> <br />C:\TEMP\bldg code 2-13-02 inc. doc <br /> <br />9 <br />