<br />- '476 <br /> <br /> <br />-3- <br /> <br />a. Internal: 6,000 square feet. <br />b. Corner: 7,500 square feet. <br /> <br />(2) Minimum lot frontage on a public street: <br /> <br />a. Internal: 50 feet. <br />b. Corner (side street): 60 feet. <br /> <br />(3) Minimum lot depth: 100 feet. <br /> <br />(4) Minimum depth of front setback: 25 feet. <br /> <br />(5) Minimum depth of front setback: 20 feet. <br /> <br />(6), Minimum width of side setback: <br /> <br />a. Internal lot: 10 feet. <br />b. Corner lot (side street): 15 feet. <br /> <br />(7) Maximum building coverage as a percentage of lot area: 50%. <br /> <br /> <br />.. <br />(8) Maximum accessory building coverage as a percentage of rear yard: <br />30%. <br /> <br />(9) Maximum height of structures: Structures located within 200 feet of a <br />residentially zoned property shall be limited to a maximum height of <br />25 feet. No limit on height beyond 200 feet from a residentially zoned <br />property. <br /> <br />! SECTION 8. Division 27 of Article 5 of Chapter 114 of the San Marcos City Code <br />j is renumbered as Division 28 of that Article and Chapter and is revised to read as follows: <br />I <br /> <br />DIVISION 28 - LI LIGHT INDUSTRIAL DISTRICT <br /> <br />Section 114.531. Permitted Uses. <br /> <br />The uses permitted in the Lllight industrial district are as follows: <br /> <br />(1) Administrative offices. <br />(2) Back-office telecommunications operations including customer <br />service centers and telemarketing operations. <br />(3) Research, development and pilot manufacturing facilities, subject to <br />the standards listed in subsection (6) of this section. <br />(4) Biomedical facilities including the manufacturing and processing of <br />pharmaceuticals, biological products, and medical equipment, subject <br />to the standards listed in subsection (6) of this section. Allowed uses <br />in this subsection shall not include biological or medical waste <br />facilities. <br />(5) Distribution centers, subject to the standards listed in subsection (6) <br />of this section. <br />(6) Manufacturing, fabrication, assembly, repair, compounding, <br />packaging, treatment, processing, and distribution facilities subject to <br />I the following standards: <br /> <br />a. All activities other than loading or storage shall be conducted <br />wholly within a completely enclosed building; <br />b. Exterior storage facilities for raw materials, partially completed <br />products or finished products shall be limited to 15% of the <br />gross square footage of all enclosed buildings; <br />c. All exterior storage facilities visible from a public street or <br />adjoining a non-industrial district shall be screened from view <br />by a wall, opaque fencing or landscaping; <br />