My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Res 1995-042
San-Marcos
>
City Clerk
>
03 Resolutions
>
1990 s
>
1995
>
Res 1995-042
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/18/2007 4:21:39 PM
Creation date
6/18/2007 4:21:39 PM
Metadata
Fields
Template:
City Clerk
City Clerk - Document
Resolutions
Number
1995-42
Date
2/27/1995
Volume Book
118
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br /> . <br /> ,~A- <br /> Inspection of Old Coca-Cola Bottling Plan t <br /> 200 Block of West San Antonio Street <br /> Building Ins-pection Performed on 8-18-93 <br /> --~ <br /> ! <br /> 1 1. The building has numerous broken windows on both levels <br /> allowing water penetration and damage to the structure. <br /> The building's condition will continue to deteriorate until <br /> the structure is weatherproofed; <br /> 2. There are numerous holes in the exterior walls allowing <br /> moisture penetration into the structure. The openings also <br /> allow rodents to enter the building; <br /> 3. There. is major ceiling finish and roof damage caused by leaks <br /> in the roof near the front stairwell; <br /> ~ <br /> 4. There is significant damage to wall framing members and the <br /> front stairwell due to roof leaks. The front stairwell serves as <br /> the primary egress from the second floor since the rear stairs <br /> do not directly access the exterior of the building; <br /> 5. Egress from the second floor is inadequate since the rear stairs <br />I exit into the warehouse area. Any reuse of the structure will <br />! require major improvements to the second floor egress; <br /> 6. Additional roof leaks are evident in other areas of the second <br /> floor; <br /> 7. What remains of the electrical system is a very old and <br /> contains fixtures and equipment that are outdated. The <br /> electrical service will have to be completely redone to meet the <br /> requirements of the National Electric Code; <br /> 8. The structure is not equipped with a toilet facility that will <br /> meet current building codes; <br /> EXHIBIT A <br />
The URL can be used to link to this page
Your browser does not support the video tag.