My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Res 1995-082
San-Marcos
>
City Clerk
>
03 Resolutions
>
1990 s
>
1995
>
Res 1995-082
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/19/2007 10:28:19 AM
Creation date
6/19/2007 10:28:19 AM
Metadata
Fields
Template:
City Clerk
City Clerk - Document
Resolutions
City Clerk - Type
Agreement
Number
1995-82
Date
4/28/1995
Volume Book
118
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br /> (19AIA <br /> WlLTEL <br /> C. ELECTRICAL <br /> The Equipment Room must have a dedicated 208 Volt, 3 phase service panel. <br /> The panel is to be mounted in the Equipment Room and should serve only <br /> telecommunications equipment. Lights and other non-telecommunications <br /> equipment cannot be served out of this panel. This panel should also have <br /> an isolated ground bus and isolated neutral bus. <br /> The panel feeder cable should be sized to meet or exceed the maximum <br /> current draw specified below. <br /> CALCULATE FEEDER CABLE WITH THIS CHART <br /> Constant Total <br /> Otv Current Current <br /> Misc. Circuits -L x ;20 A = ~ <br /> Each Cabinet - x ~6 A = - <br /> Voice Mail - x 16 A = - <br /> 24V Transformers - x 0.12 A = - <br /> Each 30 Amp. DC Rectifier -1- x 12 A = -2lL <br /> Expected Current in Feeder 60 Amps <br /> D. QUALITY OF POWER <br /> It is the Customer's responsibility to provide clean, sFeady state power. <br /> Since the power is usually provided by a common power source (the utility <br /> company) which is shared by noise and impulse generating motors and <br /> relays, a means must be provided to insure that unclean power does not <br /> enter the telecommunications equipment. A power line conditioner is the <br /> most common way of providing clean power. <br /> Telecommunications equipment requires a constant low impedance source <br /> which limits normal mode noise to less than 10 volts and common mode noise <br /> to less than 0.5 volts. In addition the conditioner must meet IEEE <br /> standard 587. A conditioner meeting these specifications is manufactured <br /> by ONEAC Corporation. WilTel requires, as a condition of the warranty <br /> agreement, that all telecommunications equipment supplied or connected to <br /> the system have a separate or common Conditioner in-line with the power <br /> source. <br /> E. GROUNDING <br /> A Dedicated Isolated Ground Bus Bar is required in the SL-l AC service <br /> panel (also called sub-panel). This isolated ground bus must be connected <br /> to the Building Electrical Earth Ground Reference. The conductor shall be <br /> a separate, uninterrupted, insulated wire of the same size (or larger) as ~ <br /> the largest current carrying feeder conductor. <br /> Customer: ~. <br /> Revised 9/24/94 Page 2 of 10 WilTel: <br />
The URL can be used to link to this page
Your browser does not support the video tag.