My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Res 1990-111
San-Marcos
>
City Clerk
>
03 Resolutions
>
1990 s
>
1990
>
Res 1990-111
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2007 4:23:50 PM
Creation date
7/30/2007 4:23:50 PM
Metadata
Fields
Template:
City Clerk
City Clerk - Document
Resolutions
City Clerk - Type
Agreement
Number
1990-111
Date
9/24/1990
Volume Book
100
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
191
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br /> 98 <br /> RAMON LUCIO, RIO VISTA, RIO VISTA ANNEX, AND BICENTENNIAL <br /> PARKS RECREATION DEVELOPMENT <br /> TECHNICAL SPECIFICATION 4 <br /> CONCRETE WORK - GENERAL <br /> 4-01 GENERAL: <br /> a. All work under this specification is subject to the <br /> applicable Items of the Texas State Department of Highways and <br /> Public Transportation "Standard Specifications for Construction of <br /> Highways, Streets, and Bridges," 1982. <br /> 4-02 SCOPE: <br /> a. This specification shall consist of constructing the <br /> Portland Cement concrete items listed below with reinforcing steel, <br /> subgrade preparation, structural excavation, and finish to the <br /> lines, grades and details as shown on the drawings and/or as <br /> directed by the Engineer. <br /> (1) restroom buildings <br /> (2) group shelter slab <br /> (3) curb and gutter <br /> (4) valley gutter <br /> (5) sidewalks <br /> (6) low water crossing <br /> (7) pedestrian bridges <br /> (8) picnic table slabs <br /> (9) miscellaneous post footings <br /> (10) filtration/detention splitter box <br /> (11) filtration/detention catch basin <br /> (12) other miscellaneous concrete <br /> b. Pedestrian Bridges' Drilled Shafts shall be as shown on <br /> the drawings and specified in Specification 7, Drilled Shaft. <br /> 4-03 MATERIALS I <br /> a. All concrete (except for miscellaneous footings) shall be <br /> class C (3600 psi min. compressive 28-day strength, minimum 6.0 <br /> sack cement per cu))J:c yard, maximum water cement ratio of 6. 0) and <br /> shall conform to the pertinent requirements of Item 421 of the <br /> Texas SDHPT Standard Specifications. <br /> 4-1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.